Bll-1000; Bll System Messages - Brocade Communications Systems SN3000B Reference

Message reference
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

BLL System Messages

BLL-1000

Message
<timestamp>, [BLL-1000], <sequence-number>, FFDC, CRITICAL, <system-name>, ASIC
driver detected Slot <slot number> port <port number> as faulty (reason:
<reason>).
Probable Cause
Indicates that a blade regulation problem was reported on the specified slot. The blade is faulted.
The possible reason codes are as follows:
Recommended
Make sure the blade is seated correctly. If the blade is seated correctly, restart or power cycle the
Action
blade.
Fabric OS Message Reference
53-1002448-01
1 = Available buffer overflow
2 = Backend port buffer timeout
3 = Backend port was shut down
4 = Embedded port buffer timeout
5 = Excessive busy mini buffer
6 = Excessive RCC VC on E_Port
7 = Excessive RCC VC on FL_Port
8 = Fail detection buffer tag error
9 = Fail detection TX parity error
10 = EPI CMEM interrupt error
11 = CMI interrupt error
12 = Interrupt overrun
13 = FDET interrupt
14 = Interrupt suspended
15 = Filter LISTD error
16 = Unknown filter LIST error
17 = Wait for LPC open state
18 = Wait for Old port state
19 = Wait for Open init state
20 = TX parity error
21 = RAM parity error
22 = BISR or RAMINIT error
Chapter
8
87

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brocade 8/12cBrocade 8/24cFabric os v7.0.1

Table of Contents