Clock Summer-Time Date - Dell PowerConnect 6224 Command Line Interface Manual

6200 series systems
Hide thumbs Also See for PowerConnect 6224:
Table of Contents

Advertisement

acronym — The acronym for the time zone to be displayed when
summertime is in effect. (Range: Up to four characters)
Default Value
No default setting
Command Mode
Global Configuration
User Guidelines
No specific guidelines
Examples
console(config)# clock summer-time recurring 1 sun jan
00:10 2 mon mar 10:00 offset 1 zone ABC

clock summer-time date

Use the clock summer-time date {date|month} {month|date}
{date|month} {month|date}
command to set the summertime offset to UTC. If the optional parameters
are not specified, they are read as either '0' or '\0', as appropriate.
Syntax
clock summer-time date {date|month} {month|date}
{date|month} {month|date}
date — Day of the month. (Range: 1–31)
month — Month. (Range: The first three letters by name; jan, for
example.)
year — Year. (Range: 2000–2097)
hh:mm — Time in 24-hour format in hours and minutes. (Range: hh:
0–23, mm: 0–59)
offset — Number of minutes to add during the summertime. (Range:
1–1440)
1106
Clock Commands
year hh:mm
[offset
year hh:mm
[offset
year hh:mm
offset
acronym
] [zone
year hh:mm
offset
acronym
] [zone
]
]