Examples
The following example enables the device to use Simple Network Time
Protocol (SNTP) to request and accept SNTP traffic from servers.
console(config)# sntp unicast client enable

clock timezone hours-offset

Use the clock timezone [ hours-offset ] [minutes
acronym
] command to set the offset to Coordinated Universal Time (UTC).
If the optional parameters are not specified, they will be read as either '0' or
'\0, as appropriate.
Syntax
clock timezone hours-offset [minutes
hours-offset — Hours difference from UTC. (Range: –12 to +13)
minutes-offset — Minutes difference from UTC. (Range: 0–59)
acronym — The acronym for the time zone. (Range: Up to four
characters)
Command Mode
Global Configuration
Default Value
No default setting
User Guidelines
No specific guidelines
Example
console(config)#clock timezone -5 minutes 30 zone IST

no clock timezone

Use the no clock timezone command to reset the time zone settings.