The default maximum header size is 128.
Command Mode
Global Configuration mode.
User Guidelines
This command has no user guidelines.
Example
console(config)#sflow 1 sampling ethernet 1/g2 1500 50

sflow sampling (Interface Mode)

Use the sflow sampling command in Interface Mode to enable a new sflow
sampler instance for this data source if rcvr_idx is valid. Use the "no" form of
this command to reset sampler parameters to the default.
Syntax
rcvr-index
sflow
rcvr-index
no sflow
rcvr-index — The sFlow Receiver for this sFlow sampler to which flow
samples are to be sent. If no receiver is configured, then no packets will be
sampled. Only active receivers can be set. If a receiver expires, then all
samplers associated with the receiver will also expire. (Range: 1 - 8).
sampling-rate — The statistical sampling rate for packet sampling from
this source. A sampling rate of 1 counts all packets. A rate of 0 disables
sampling. A value of n means that out of n incoming packets, 1 packet will
be sampled. (Range: 1024 - 65536).
size — The maximum number of bytes that should be copied from the
sampler packet (Range: 20 - 256 bytes).
Default Configuration
There are no samplers configured by default.
The default sampling rate is 0.
The default maximum header size is 128.