Parameter
TIMESYNC Time Adjustment = [+ or -
] hour:minute:second [at month/day/
year hour:minute:second AM or PM]
TIMESYNC Time Source:
server_name
TIMESYNC Type =
type_of_time_source
TIMESYNC Write Parameters = value Specify whether parameters specified by the TIMESYNC Write
TIMESYNC Write Value = number
230 Utilities Reference
Use to
Specify when a time adjustment will take place.
Note: You cannot use this parameter on a secondary time server.
Maximum: 99 characters
Default: None scheduled
Use this parameter sparingly to correct network-wide time errors.
Default date and time is six polling intervals or 1 hour (whichever
is longer) from the current time.
Misuse of this parameter can corrupt time synchronization and
the order of events on your network.
Specify a server as time source. If no server name is entered, the
parameter displays the list of configured servers.
Use EDIT, rather than this parameter, to add a server to the
configuration list in the TIMESYNC.CFG file.
Maximum: 48 characters
Specify the default time source type.
Use EDIT, rather than this parameter, to specify the default time
source type in the TIMESYNC.CFG file.
Supported types: reference, primary, secondary, single
reference
Default: Single reference
Value parameter are written to the configuration file.
Supported values: ON, OFF
Default: OFF
Control which parameters are written by TIMESYNC Write
parameters.
Supported values:
1 = Write internal parameters only
2 = Write configured time sources only
3 = Write both parameters and configured time sources
Default: 3