Bay Networks Nautica 200 Reference Manual page 47

Nortel nautica 200: reference guide
Hide thumbs Also See for Nautica 200:
Table of Contents

Advertisement

Parameter:
Function:
Parameter:
Instructions:
Parameter:
Function:
117237-C Rev. A
The parameters involved are as follows:
MLink-Enable (Multilink)
With this option enabled, when the threshold limits are
reached for a path (see page 4-17), MPP will bring up a
second link for additional bandwidth.
This attribute can be used in conjunction with the
BACP-Enable attribute.
BACP-Enable
BACP controls whether a dial-in user can obtain
additional bandwidth. This is achieved by either
allowing or disallowing extra calls.
The unit receiving the call supplies a BACP callback
number to the unit making the call. This calling unit
dials the callback number to obtain the extra bandwidth.
For more information on BACP callback numbers, refer
to page 4-24 or
Note:
If BACP is enabled, MLink must also be enabled, and
the path on which BACP is set must have cnum values.
Demand Threshold (Nautica Wizard)
Dem-Thresh-PC (BCC)
Demand Threshold PC is a percentage utilization of the
total bandwidth of the path. The second channel will be
brought up automatically when the first channel is used
this much.