Bay Networks Nautica 200 Reference Manual page 220

Nortel nautica 200: reference guide
Hide thumbs Also See for Nautica 200:
Table of Contents

Advertisement

NauticaRS Release 4.1 Reference Guide
Parameter:
MTC:
Default:
Options:
Function:
Parameter:
MTC:
Default:
Options:
Function:
7-38
e1-FrameType
e1
crc4
crc4, noncrc4
The default here is crc4, the only other option allowed is
noncrc4. With this option set to CRC4 frame checking is
turned on. Make sure that the PRI provider supports this
option.
BCMapMode
bcm
onetoone
onetoone, none, alltoone, unstructured, configured
With Fractional mode turned on, it is possible to map
B Channels to specific WAN ports. In this way a point to
point link (rather than an ISDN link) is created. More
than one channel can be mapped to a WAN port.
The default value here of onetoone means that one B
channel is mapped to one WAN port. To increase the
amount of information passed through WAN ports, you
may want to increase the number of channels per port.
The values available for this option are as follows:
OneToOne: Each B channel is mapped to a single
WAN device, for example, 1 - WAN01, 2 -
WAN02.
None: This disables the mapping.
AllToOne: All available channels are mapped to a
single WAN device giving 2 MBits worth of
bandwidth.
Unstructured: The e1 framing channel is also used
for data, giving 2 MBit leased line. This option can
only be used on Nautica to Nautica connections.
117237-C Rev. A