NauticaRS Release 4.1 Reference Guide
Parameter:
MTC:
Default:
Options:
Function:
Parameter:
MTC:
Default:
Options:
Function:
Instructions:
4-36
Min-Call-Length
min-c
0
A number of seconds from 0 to 600
Changing this option to anything other than 0 sets the
minimum length for a call. For example, if your ISDN
Service Provider always charges you for the first minute
of every call, set this value to 58.
Compression-Type
comp
Any
Any, none, staclz, mppc, wcp
A compression type to be used when this path is in use
Select the type of compression you want to use on this
path. Set the parameter to None if compression is not
supported, or select Any if you are unsure.
•
MPPC: Microsoft Point to Point Compression.
•
StacLZ: Compression algorithm developed by Stac
Electronics.
•
WCP: WAN Compression Protocol as used by
many BayRS routers.
•
Any: Any of the above (apart from WCP) will be
negotiated in order of priority: MPPC then StacLZ.
Note:
WCP is only used when it specified by itself. It does not
run with the Any option.
117237-C Rev. A