Exhaust Adapter Installation - BRP Evinrude E-TEC G2 Service Manual

Hide thumbs Also See for Evinrude E-TEC G2:
Table of Contents

Advertisement

Exhaust Adapter Installation

Install the adapter and exhaust pipe into the
exhaust housing.
From the bottom of the exhaust housing, align the
water tube into the large opening. Then push it
rearward to install it into the casting.
1
1. Large opening
Carefully install the foam gasket onto the adapter.
Next install the muffler and hose from the exhaust
pipe. Secure the muffler hose to the exhaust pipe
with a new Oetiker clamp. Then install the two
hoses onto the hose fittings. Secure with tie
straps.
4
1. Foam gasket
2. Muffler
3. Hose clamp
4. Tie straps
Install the two adapter screws. Tighten to a torque
of 22 to 24 Ft. lbs. (30 to 32 N·m).
1
009346
1. Adapter screws
009345
Exhaust Housing & Adapter
Exhaust Housing Service
2
1
4
3
009343
009344
12