Dps System Calibration - BRP Evinrude E-TEC G2 Service Manual

Hide thumbs Also See for Evinrude E-TEC G2:
Table of Contents

Advertisement

DPS System Calibration

WARNING
The DPS system of AFA and newer outboards
REQUIRES calibration when:
installing multiple outboards
(initial installation)
replacing a DPS module
replacing a steering pressure sensor
replacing a steering position sensor
Failure to complete DPS system calibration
can cause damage to the tie bar(s) and/or the
transom of the boat due to overloading.
Steering Pressure Sensor Calibration
(AFA and Newer Models Only)
IMPORTANT:
Calibrate the pressure sensor
when:
replacing a DPS module
replacing a steering pressure sensor
Connect a piece of tubing to each bleed valve.
Insert the open end of the tubing into a container
appropriate for collecting hydraulic steering fluid.
1. Bleed valves
Open the both bleed valves at least one-half turn
to relieve pressure on the hydraulic steering sys-
tem.
Wipe up any spilled steering fluid with shop tow-
els.
ENVIRONMENTAL NOTE:
Dispose of contaminated shop towels according
to local environmental regulations.
1
1
009396
Use Evinrude Diagnostics software v 6.1 or higher
to calibrate steering pressure sensors.
Connect the MPI-2 and adapter cable to the lap-
top and the NMEA 2000 network. Turn the key
switch to the ON position, then start the diagnostic
program.
After the program connects to the network, select
from the device list the Engine Controller (EMM).
Then select the Power Steering button.
1. Select Enable Calibration, The power steering
pump is disabled while in calibration mode.
1. Enable Calibration
2. Select Zero Pressure Sensors. The button will
deactivate while setting the ZERO point. Wait
for the button to activate BEFORE continuing.
3. Select Disable Calibration to save the setting
and re-enable the power steering pump.
1. Zero Pressure Sensors
2. Disable Calibration
Stern and Swivel
DPS Module Service
1
2
009397
2
1
009398
309
13

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

E 250 l ho ag b

Table of Contents