Vapor Vent Solenoid Circuit Test
Remove the electrical connector from the vapor
vent solenoid.
Use the diode test function of a digital multimeter
with appropriate test probe leads to check the sig-
nal circuit.
Connect the negative meter lead to the wire listed
in the table, connect the positive meter lead to
engine ground.
Vapor Vent Solenoid Circuit Diode Test
Wire
BROWN/YELLOW
Results:
No reading (OL or
) indicates an open circuit.
A reading of zero (0) indicates an short circuit.
Isolate the faulty component. Check wiring and
connections. Repair or replace faulty wiring.
Use a digital multimeter with appropriate test
probe leads to measure the resistance of the
vapor vent solenoid ground circuit.
Connect the positive meter lead to the engine har-
ness connector wire listed in the table. Connect
the negative meter lead to engine ground.
Vapor Vent Solenoid
Ground Circuit Resistance
Wire
BLACK
Results:
An infinite reading (
) indicates an open circuit.
Isolate the faulty component. Check wiring and
connections. Repair or replace faulty wiring.
Pin
Result
approximately
1
0.5 VDC
Pin
Result
< 1 Ω
2
Electric Fuel Lift Pump Resistance Test
Disconnect the battery cables at the battery.
Remove the electrical connector from the fuel
pump and vapor separator assembly.
Use a digital multimeter with appropriate test
probe leads to measure the fuel pump coil resis-
tance.
Connect the black meter lead to the black wire,
connect the red meter lead to the red wire.
Fuel Pump Resistance
<10 Ω @ 77°F (25°C)
Electric Fuel Pump Circuit Test
Remove the electrical connector from the fuel
pump and vapor separator assembly.
Use the diode test function of a digital multimeter
with appropriate test probe leads to check the sig-
nal circuit.
Connect the negative meter lead to the wire listed
in the table, connect the positive meter lead to
engine ground.
Fuel Pump Circuit Diode Test
Wire
BROWN/WHITE
Results:
No reading (OL or
) indicates an open circuit.
A reading of zero (0) indicates an short circuit.
Isolate the faulty component. Check wiring and
connections. Repair or replace faulty wiring.
Fuel System
Fuel System Tests
009205
Pin
Result
approximately
3
0.5 VDC