BRP Evinrude E-TEC G2 Service Manual page 124

Hide thumbs Also See for Evinrude E-TEC G2:
Table of Contents

Advertisement

Electrical and Ignition
Ignition System
Connect the negative meter lead to the red/white
wire of a known good circuit such as a fuel injec-
tor.
Ignition 55V Circuit Resistance
Wire
WHITE/RED
Results:
An infinite reading (
Isolate the faulty component. Check wiring and
connections. Repair or replace faulty wiring.
Ignition Ground Circuit Resistance Test
Use a digital multimeter with appropriate test
probe leads to measure the ground circuit resis-
tance.
Make sure the key switch is in the OFF position.
Connect the positive meter lead to the engine har-
ness connector wire listed in the table. Connect
the negative meter lead to engine ground.
Ignition Ground Circuit Resistance
Wire
BLACK
Results:
An infinite reading (
Isolate the faulty component. Check wiring and
connections. Repair or replace faulty wiring.
Ignition Control Circuit Voltage Test
Disconnect the electrical connector from the igni-
tion coil.
Use a digital multimeter with appropriate test
probe leads to measure signal circuit voltage.
Connect the positive meter lead to the engine har-
ness connector wire listed in the table. Connect
124
Pin
Result
< 1 Ω
3
) indicates an open circuit.
Pin
Result
< 1 Ω
1
) indicates an open circuit.
the negative meter lead to engine ground. Turn
the key switch to the ON position.
1. Engine harness connector (ignition coil)
Ignition Circuit Voltage
Wire
ORANGE/BLUE
(upper cylinder)
ORANGE/PURPLE
(middle cylinder)
ORANGE/GREEN
(lower cylinder)
Capacitor Test
IMPORTANT:
Make sure the capacitor is dis-
charged before testing.
Disconnect the capacitor from electrical harness.
Use an ohmmeter set on the high ohms scale to
test the capacitor. Connect the meter leads to the
capacitor terminals:
If the capacitor is working correctly, it will store
energy from the meter. The resistance reading
will increase until it goes to (nearly) infinity.
If the capacitor is shorted, the reading will
immediately show full continuity.
If there is an open circuit in the capacitor, the
meter will show no continuity.
If the resistance reading starts as a negative num-
ber, or the reading goes down in value, the capac-
itor already retains some stored energy. Ground
the capacitor and test again.
1
009358
Pin
Result
2
2
5 to 7 VDC
2

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

E 250 l ho ag b

Table of Contents