Engine and Control Systems
Diagnostic Software Functions
Occurred Faults
The Occurred Faults screen displays the code
number, the number of times the event occurred,
and operating hours of first and last occurrences.
Occurred Faults Review Screen
Historical Faults
The Historical Faults screen displays a history of
all previous occurred codes, including code num-
ber, the number of times the event occurred, and
operating hours of the last occurrence.
Historical Faults Screen
Settings
Powerhead Break-In
Use the diagnostic software to initiate break-in oil-
ing. Break-in is a predetermined oiling program
92
that runs for two hours of outboard operation,
above 2000 RPM.
1
Settings Screen
1. Break-in oil setting
Ignition Timing
009282
Use the Timing Verification screen to check and
adjust EMM timing. EMM timing must be synchro-
nized to crankshaft position.
Refer to Timing Adjustments on p. 136.
Settings Screen
1. Timing Verification
009288
Check timing after replacing a powerhead, crank-
shaft or flywheel.
IMPORTANT:
and the outboard reaches operating temperature
before making adjustments.
1
Make sure the timing pointer is set
009243
009423