Icon Ii System Fault Detection - BRP Evinrude E-TEC G2 Service Manual

Hide thumbs Also See for Evinrude E-TEC G2:
Table of Contents

Advertisement

ICON II System Fault Detection

Type
Condition Code or Warning
Controllable
Critical
A critical fault will prevent normal operation and result in the system entering a failed state. The control
will:
send "not available" data in the throttle and gear messages
deactivate SYNC, NEUTRAL and Throttle Warm-Up modes
send the fault message and store the fault in the remote control memory
flash the appropriate remote control LED(s) five times per second
When the control detects the outboard(s) are in NEUTRAL idle and the working lever(s) are in NEU-
TRAL, the system returns to normal operation.
Description
A conditional fault requiring
remedial action to correct that
does not affect normal
operation.
Example: Attempt to start
outboard(s) with control
lever(s) not in NEUTRAL.
Faults that allows for a fully
controllable remedial action.
Example: Low battery
voltage.
Faults that result in the
inability to accurately
determine critical outboard
commands.
Example: Communication
between the control and
outboard(s) EMM(s) is lost.
Evinrude ICON II Remote Control System
ICON II System Fault Detection
Response
Response based on condition
- upon resolution the system
will resume full performance.
Informational only.
Commanded lever and gear
positions become
unavailable. Outboards set to
S.A.F.E. mode.
Indication
Condition specific warning
message appears on digital
display.
Control LEDs flash five times
per second.
Warning message appears
on digital display.
231
10

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

E 250 l ho ag b