Routine Service
Rigging Information
Water Pressure Connection
To send water pressure data to the EMM, along
with an NMEA 2000 display, install 50 psi Water
Pressure Transducer Kit, P/N 5008640.
Water pressure readings in excess of 40 psi (275
kpa) are possible at boat speeds in excess of
50 mph (80 kph/43 kts).
Remove the accessory water pressure plug from
the engine. Refer to the installation instructions
provided with the water pressure transducer kit.
IMPORTANT:
Use the fittings and hose supplied
with the kit. Do NOT install the transducer directly
into the block.
1. Accessory water pressure plug
Use the Configuration screen of Evinrude Diag-
nostics software v6.1 to set the water pressure
transducer.
1
1. Water pressure transducer
Connect the transducer lead to the engine wiring
harness connector.
36
1
009119
009237
Install the rigging hose to the entry port of the rig-
ging center. Install the cover into place below the
cable entryway.
1
1. Rigging hose installation
2. Cover
If removed, install cable entryway end cap. Turn
the end cap 90° to lock it into place.
1. Rigging center end cap
Hose and Cable Clips
After completing connections, re-position the two
clips, P/N 352531, from the fuel and oil supply
hoses as shown:
Attach one clip to the fuel hose and oil supply
hose.
Attach the second clip to the oil supply hose
and positive battery cable.
2
009094
1
009391