Primary Alarm Output Pwd
Secondary Alarm Output ID
Secondary Alarm Output Pwd
Com. Port Thruput
Com. Port Parity:
Com. Port Stopbit
Bits per Character
Collecting Node
Configuring Node-Wide Default Parameters
if it is available. Problems with the secondary device will not stop delivery to the
primary device.
If specifying an async port to a printer, be sure to configure the
profile
(see Chapter 12) to match the line speed of the printer. (Do not con-
figure the port for
is a password that will be used with the
lecting node, the local FRX4000/6000's
match the collecting node's
is used for a collecting node to send alarms to a second location other than that spec-
ified by the
Primary Alarm Output ID
nodes.
is a password that will be used if the
also associated with a password. If so, both passwords must match.
is the line speed (in bits per second) through the COM port:
= 110 bps
A
B
= 1200 bps
E
F
sets the parity bit, which is used to detect changes in bit structure of the data from
origin to destination:
sets 1 or 2 stopbits, which signal the end of a character.
sets the bit value at 7 or 8 per character.
is an FRX4000/6000 to which alarms are sent from other Cabletron frame relay access
devices. Any of these devices can be a collecting node; which nodes send their alarms
to a collecting node is determined by the
the other nodes; these must match the
lecting node.
The number of nodes that can report to a collecting node depends on the number of
connections that can exist on the collecting node. (An FRX4000 supports up to 512
connections; an FRX6000 supports up to 512 per RLP.) A connection on a collecting
node is required for each reporting device.
Do not configure a collecting node to send its alarms to another
collecting node. The alarms will be ignored, due to a format mis-
match.
.)
Autobaud
Primary Alarm Output ID
Primary Alarm Output Pwd
Collecting Node Pwd
. This parameter has no function on non-collecting
Secondary Alarm Output ID
= 150 bps
= 300 bps
C
= 2400 bps
= 4800 bps
G
= None,
= Odd,
0
1
3
Primary Alarm Output ID
Collecting Node ID
. If that ID is a col-
(Password) must
.
is an address that is
= 600 bps
D
= 9600 bps
H
= Even.
s and passwords of
and password of their col-
async PAD
4-5