Cabletron Systems Netlink FRX4000 User Manual page 209

Frame relay access products
Hide thumbs Also See for Netlink FRX4000:
Table of Contents

Advertisement

RTS-CTS H/W Flow Control
Disconnect Timer
Disconnect Duration
Timeout if No Login
Timeout if No Call
Timeout if No Data
Configuring Async Ports
enables hardware flow control through stop/start of data using RTS (pin 4), CTS (pin
5), and CD (pin 8) on the RS-232 interface. Flow control is usually necessary to
maintain communication without data loss between devices or channels with different
throughput capabilities.
RTS-CTS flow control works only on a physical DTE port, as physical DCE ports
have RTS looped back internally to CTS.
The other common method of flow control is XON-XOFF (parameters 5 and 12 of the
async PAD profile); however, when the data itself is likely to contain these characters
(for example, in a binary file), XON-XOFF may become inadequate.
is an inactivity timer that determines the length of time the port can go without trans-
mitting or receiving characters, as determined by the parameters
, and
Timeout if No Call
seconds after the number of minutes specified.)
is the length of time the PAD will drop the modem signals after logout of the user
(whether caused by a timeout or user command). For a dial-in line, this should be set
to something greater than
nected after a timeout or logout. For a leased or directly connected line,
should be
, to avoid disconnections.
Duration
0
if
, starts the disconnect timer the moment the user enters login state; e.g., when DSR
Y
is asserted on the modem, or when a direct-connect user logs out. As long as the dis-
connect timer has not expired, the user can continue to attempt to log in. On a dial-in
line, if the timer has expired and
will be initiated. (The modem signals will be dropped.)
If the user logs out, the
be disconnected.
This parameter should be
will periodically be output. (This is harmless, but unnecessary.)
This parameter is automatically disabled on a PVC connection.
if set to
, starts the disconnect timer as soon as the user logs in or a virtual circuit is
Y
cleared, and the PAD is ready to receive commands from the user. The timer is reset
every time the port receives or transmits a call.
This parameter is automatically disabled on a PVC connection.
if set to
, starts the disconnect timer as soon as a virtual circuit is connected. The timer
Y
is reset every time the port receives or transmits a character. If
user has escaped from the data transfer state (by pressing
the port will not be output through the port.
When the disconnect timer expires, the software will check for any data waiting to be
output, as well as the state of the user. If there is data waiting and the user has escaped
. (The actual timeout may be up to thirty
Timeout if No Data
, to ensure that the line does not remain physically con-
0
Disconnect Duration
will be ignored, and the line will immediately
Disconnect Timer
for a leased line; otherwise, the PAD banner and prompt
N
Timeout if No Login
Disconnect
is not
, a physical disconnect
0
is specified and the
Y
), any data sent to
[Ctrl] [P]
,
12-13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Netlink FRX4000 and is the answer not in the manual?

This manual is also suitable for:

Frx6000Netlink frx6000

Table of Contents