21-12
426.
PU Status p = "n" stn = 0x"n" status = "n"
Severity:
2
Meaning:
The SDLC PU status has changed.
Action:
None.
428.
Duplicate of DLCI "n" on Port
Severity:
3
Meaning:
Each connection sharing a DLCI must be on a different logical port,
and two records have been configured specifying the same logical
port on one DLCI. (DLCIs are configured in records for logical
ports, IP/LLC2/IPX interfaces over frame relay, Bridge ports, and
frame relay PVCs.) Only one of the duplicate connections will come
up.
Action:
Check the database records for the duplicate configuration and
change one (or more) of the records.
429.
File Update:FRDLCI.DAT
Severity:
4
Meaning:
The Frame Relay DLCI configuration file has been updated.
Action:
None.
430.
Received Port Disable Request
Severity:
1
Meaning:
Self-explanatory.
Action:
None; however, all users of this port should be made aware of the
disable.
431.
Received Port Dump Request
Severity:
1
Meaning:
The BSC device has experienced a problem that caused it to send a
request to send a dump to the port.
Action:
Check the device.
432.
Node Under Remote Control
Severity:
4
Meaning:
Self-explanatory.
Action:
None.
433.
Remote Control Released
Severity:
4
Meaning:
Self-explanatory.
Action:
None.
FRX4000/FRX6000 4.0 User Guide, Rev 01
Need help?
Do you have a question about the Netlink FRX4000 and is the answer not in the manual?