Translation Template Parameters; Replacing Called/Calling Address Or User Data - Cabletron Systems Netlink FRX4000 User Manual

Frame relay access products
Hide thumbs Also See for Netlink FRX4000:
Table of Contents

Advertisement

Translation Template Parameters

Replacing Called/Calling Address or User Data

8-30
Table 8-7 Translation Template Parameters
Parameter
1
Template Name
Called Address
Calling Address
User Data
Protocol ID
Facilities
Used simply for ease of identification.
1
These determine the translation formula:
2
= Pass through unchanged.
P
R
= Remove entire field.
L
= Replace with literal digit.
= Replace with original called address.
X
= Replace with original calling address.
G
U
= Replace with original user data.
T
= Replace with ASCII text.
If replacing all or part of a field, see "Replacing (field type)" over the next few pages.
All wild cards are valid in the translation template, allowing one template to function
for many calls.
The FRX4000/6000 routes traffic based on the user data field if the
present in the SVC routing table. The gateway also allows the
include user data field operations.
To replace all or part of any of these fields, press
Maintenance Menu. When prompted, enter the desired information as described
below:
= Literal digits, which means that the actual digits you enter here will replace that
L
same number of digits in the specified field. Type
the desired digits,
in the selected part of the field with the actual numbers
= Called address. The characters entered here are not necessarily the exact char-
X
acters of original called address, but rather the characters (digits or wildcards) of
the template ID that match the original called address (that part not already trans-
lated).
Type
followed (with no spaces) by the desired characters,
X
which positions of the 15 digits in the original called address are to replace the
selected portion of the packet. For example, typing
second, third, and fourth characters of the (remaining) original called address part
of the template ID.
Valid Values
0–31 characters
P,R,L,X,G,U
P,R,L,X,G,U
P,R,L,X,G,U,T
0–8 characters
P ,
P ,R,
. For example, typing
0–9
Default Value
none
2
P
2
P
2
P
2
P
2
0–218 characters
P
U
operator, and can
U
or
at the Translation Template
[B]
[C]
followed (with no spaces) by
L
will replace four digits
L1234 [Enter]
.
1234
,
1–9
X1234 [Enter]
FRX4000/FRX6000 4.0 User Guide, Rev 01
operator is
, indicating
A–F
takes the first,

Advertisement

Table of Contents
loading

This manual is also suitable for:

Frx6000Netlink frx6000

Table of Contents