21-10
405.
Restart with cc "n" dc "n"
Severity:
4
Meaning:
A Restart has been issued, with the cause code (
code (
Action:
Depends on the cause. If necessary, contact
Technical
406.
Operational
Severity:
2
Meaning:
For all ports except those noted below, this means that the link is up.
For SNA TPAD, this means that the XID exchange has been per-
formed, and the XID data received in the response frame matches
the XID data configured for the TPAD subscriber. The link is ready
to establish an X.25 connection with the remote HPAD.
For SNA HPAD, this means that an XID or SNRM command frame
has been received for at least one of the link addresses configured for
the HPAD subscriber. The link is ready to establish an X.25 con-
nection with the remote TPAD.
Action:
None.
407.
Call Clr LCN = "n" cc = "n" dc = "n"
Severity:
4
Meaning:
Self-explanatory. See
diagnostic codes (
Action:
Depends on the cause. If necessary, contact
Technical
408.
End of IPL
Severity:
4
Meaning:
Self-explanatory.
Action:
None.
409.
PVC is Up
Severity:
4
Meaning:
Self-explanatory.
Action:
None.
410.
PVC Reset
Severity:
4
Meaning:
A Reset was sent on the PVC.
Action:
None.
) shown. (See
Appendix
dc
Support. (See page 21-4.)
Appendix B
).
dc
Support. (See page 21-4.)
) and diagnostic
cc
B.)
Cabletron Systems
for a list of cause codes (
Cabletron Systems
FRX4000/FRX6000 4.0 User Guide, Rev 01
) and