Printer
Disable Status Response
Configuring BSC Interactive
causes (if
) all characters transmitted, including control character sequences, to be
Y
treated as data. This is useful for transmitting binary data, machine language computer
programs, etc., without special coding.
Data-link control character sequences transmitted during transparent mode must be
preceded by character 1/0 (DLE) in order to be recognized as control characters.
specifies whether the device has an attached printer.
determines how the BSC port will report the status of the attached device:
= Normal Status. The port will report what the device reports.
0
= No Status. The port will report status only if the device is active.
1
= Always Active Status. The port will always report the device as active.
2