BSC Batch Port Parameters

Configuring BSC Batch
BSC Batch Subscriber Information
*
RLP: 0 Port: 1
*
I/O: V.35
A Sq B Local Sub.
01
100101000000000
02
100101000000001
03
100101000000002
04
100101000000003
05
100101000000004
Select
Figure 11-2 BSC Batch Port Record, Screen 3
Table 11-1 BSC Batch Port Parameters
Parameter
Port Type
Physical Port Interface
Blocked Port Flag
Line Speed
(ms)
Retransmission Period
Maximum Retransmissions
Maximum Bytes per Frame
Generate Clock
Rcv Clock (TT) from DTE
EBCDIC
Transparent Text Supported
Ack
Controller Type
Full Duplex
# of Beginning Sync Chars
# of Trailing Pad Chars
No Response Timer
(sec)
No Response Retry Count
Delay Timer
(sec)
(continued on next page)
C Remote Sub. D Atcl
E Rtytm F Rty#
200201000000000N
60
0
211020100000000N
60
0
212202010000000N
60
0
203301000000000N
60
0
231020100000000N
60
0
Valid Values
BSC-B
see explanation
Y/N
75 bps – 19.2 Kbps
1–9999
1–99
25–4105
Y/N
2
Y/N
Y/N
Y/N
A–C
A–F
Y/N
2–10
1–10
2–10
4–255
1–10
Node Name=nodexyz
G Del
Default Value
(not valid here)
see explanation
N
1
9600 bps
2000
5
4105
Y
N
Y
Y
none
none
Y
2
1
2
5
1