Frame Relay Pvc Parameters; Frame Relay Pvc Configuration - Cabletron Systems Netlink FRX4000 User Manual

Frame relay access products
Hide thumbs Also See for Netlink FRX4000:
Table of Contents

Advertisement

Frame Relay PVC Parameters

Connection Priority
Configuring Frame Relay
PVC Maintenance Connection ID1
A PVC Type
B
Connection Priority
Connection Between Frame Relay Port...
C Primary Name
D Primary DLCI
E
Primary RLP
F
Primary Port
and Frame Relay Port...
G Secondary Name
H Secondary DLCI
I
Secondary RLP
J
Secondary Port
Option:
Figure 7-8 Frame Relay PVC Configuration
There will be no
It does not matter which end of the PVC is configured first.
Table 7-5 Frame Relay PVC Parameters
Parameter
Connection Priority
Primary/Secondary Name
Primary/Secondary DLCI
Primary/Secondary RLP
Primary/Secondary Port
1 The DLCI must match the DLCI configured at the remote end of the physical link.
prioritizes this connection for intra-nodal traffic; the higher the number, the higher the
priority. (This priority has no effect on traffic exiting a node.)
Priorities are configured on all logical interfaces that use a physical frame relay port.
The device processor in the node uses these priorities to help determine the order in
which it will process protocols.
FRL to FRL
0
fsub1
16
0
0
fsub5
21
1
2
Primary/Secondary RLP
Valid Values
0–9
0–31 characters
1
16–991
(FRX6000 only)
0–7
0–7
Node Name=node_xyz
from Main Menu
[A],[D],[E],[B]
entry on an FRX4000.
Default Value
0
none
16
0
0
7-21