7. LW3 Programmers' Reference
7.4. System Commands
7.4.1. Query the Product Name
The name of the product is a read-only parameter and cannot be modified.
Command and Response
ç GET·/.ProductName
pr·/.ProductName=<product_name>
æ
Example
ç GET /.ProductName
æ pr /.ProductName=UMX-TPS-TX140-Plus
7.4.2. Set the Device Label
ATTENTION!
The device label can be changed to a custom text in the
writable parameter is not the same as the ProductName parameter.
The default format of the device label is:
Command and Response
SET·/MANAGEMENT/UID.DeviceLabel=<Custom_name>
ç
pw·/MANAGEMENT/UID.DeviceLabel=<Custom_name>
æ
The Device Label can be 39 character length and ASCII characters are allowed. Longer names are truncated.
Example
ç SET /MANAGEMENT/UID.DeviceLabel=UMX-TPS_Control_room
æ pw /MANAGEMENT/UID.DeviceLabel=UMX-TPS_Control_room
7.4.3. Query the Serial Number
Command and Response
ç GET·/.SerialNumber
pr·/.SerialNumber=<serial_nr>
æ
Example
ç GET /.SerialNumber
æ pr /.SerialNumber=87654321
Status
tab of the LDC software. This
#devicelabel
LW_<product_name>_<serial_no>
Applied firmware packages: (UMX-TPS): v1.5.0b4 | (WP-UMX-TPS): v1.4.0b8 | (FP-UMX-TPS): v1.4.0b8 | LDC software: v2.5.6b2
UMX-TPS-TX100 series – User's Manual
7.4.4. Query the Firmware Version
Command and Response
#firmwareversion
ç GET·/SYS/MB.FirmwareVersion
pr·/SYS/MB.FirmwareVersion=<firmware_version>
æ
Example
ç GET /SYS/MB.FirmwareVersion
æ pr /SYS/MB.FirmwareVersion=1.3.2b1 r43
7.4.5. Resetting the Device
The transmitter can be restarted – the current connections (LAN, RS-232) will be terminated.
Command and Response
#reboot #reset #restart
ç CALL·/SYS:reset()
æ mO·/SYS:reset=
Example
ç CALL /SYS:reset()
æ mO /SYS:reset=
7.4.6. Restore the Factory Default Settings
Command and Response
#factorydefaults
ç CALL·/SYS:factoryDefaults()
æ mO·/SYS:factoryDefaults=
Example
ç CALL /SYS:factoryDefaults()
æ mO /SYS:factoryDefaults=
The device is restarted, current connections are terminated, and the default settings are restored. See the
complete list in the
Factory Default Settings
section.
102