WAGO-SPEEDWAY 767
767-1201 FC PROFINET IO 8DI 24V DC
Save the configuration in a project by clicking on [Accept] and [File] >
5.
[Save].
6.
Transfer the project file to the respective 767 component. To transfer
parameters, right-click on the fieldbus coupler or on the respective I/O
module and select Download Parameters to device from the context menu.
15.5.2
Online Parameter Setting
Requirement:
To configure the fieldbus coupler in online mode, the network structure of the 767
node must have been transferred to WAGOframe (see section "Parameterization
via WAGOframe" > "Setting Up Network Manually"). You can also utilize the
"Set Up Network" option as described in section "Parameterizing" > "Setting Up
Network Manually".
For offline configuration, proceed as follows:
1.
Right-click on the "<Speedway:> 0767-xxxx" device driver in the "Network
View" pane.
In the context menu, select Go online. When the progress bar reaches
2.
100%, a connection to the fieldbus coupler has been established. Repeat this
step for each desired I/O module.
Figure 47: Setting up a connection to the fieldbus coupler (example)
Manual
Version 2.2.0
Parameterization via WAGOframe
159