WAGO 750-508/040-000 Manual (60 pages)
2DO 24 VDC 2A/ Diagn XTR 2-channel digital output; 24 VDC; 2,0 A; diagnostics extreme For WAGO-I/O-SYSTEM 750 XTR
Brand:
WAGO
| Category:
Control Unit
| Size: 1 MB
Table of Contents
Table of Contents
3
Notes about this Documentation
5
Validity of this Documentation
5
Copyright
5
Symbols
6
Number Notation
8
Font Conventions
8
Table 1: Number Notation
8
Table 2: Font Conventions
8
Important Notes
9
Legal Bases
9
Subject to Changes
9
Personnel Qualifications
9
Use of the 750 Series in Compliance with Underlying Provisions
9
Technical Condition of Specified Devices
10
Disposal
10
2.1.4.1.1 Electrical and Electronic Equipment
10
2.1.4.1.2 Packaging
11
Safety Advice (Precautions)
12
Device Description
15
View
17
Figure 1: View
17
Table 3: Legend for Figure "View
17
Connectors
18
Data Contacts/Local Bus
18
Figure 2: Data Contacts
18
Power Jumper Contacts/Field Supply
19
Figure 3: Power Jumper Contacts
19
Table 4: Legend for Figure "Power Jumper Contacts
19
CAGE CLAMP Connectors
20
Figure 4: CAGE CLAMP Connectors
20
Table 5: Legend for Figure "CAGE CLAMP
20
Display Elements
21
Operating Elements
21
Figure 5: Display Elements
21
Table 6: Legend for Figure "Display Elements
21
Schematic Diagram
22
Figure 6: Schematic Diagram
22
Technical Data
23
Device Data
23
Power Supply
23
Communication
23
Table 7: Technical Data - Device
23
Table 8: Technical Data - Power Supply
23
Table 9: Technical Data - Communication
23
Outputs
24
Connection Type
24
Figure 7: Short-Circuit Limitation
24
Table 10: Technical Data - Outputs
24
Table 11: Technical Data - Field Wiring
24
Table 12: Technical Data - Power Jumper Contacts
24
Mechanical Conditions
25
Climatic Environmental Conditions
25
Table 13: Technical Data - Data Contacts
25
Table 14: Technical Data - Mechanical Conditions
25
Table 15: Technical Data - Climatic Environmental Conditions
25
Approvals
26
Standards and Guidelines
27
Table 16: Standards and Rated Conditions for Explosion Protection Applications
27
Table 17: Climatic and Mechanical Environmental Conditions and Shipbuilding
28
Table 18: EMC - Immunity to Interference
29
Table 19: EMC - Emission of Interference
31
Table 20: Standards and Rated Conditions for Rail Applications (en 50155)
32
Process Image
33
Table 21: Output Bits
33
Table 22: Input Bits
33
Mounting
34
Mounting Sequence
34
Inserting and Removing Devices
35
Inserting the I/O Module
35
Figure 8: Insert I/O Module (Example)
35
Removing the I/O Module
36
Figure 9: Snap the I/O Module into Place (Example)
36
Figure 10: Removing the I/O Module (Example)
36
Connect Devices
37
Connecting a Conductor to the CAGE CLAMP
37
Figure 11: Connecting a Conductor to a CAGE CLAMP
37
Connection Examples
38
2-Wire Connection
38
Figure 12: 2-Wire Connection
38
Figure 13: 3-Wire Connection
38
Diagnostics
39
Diagnostics Via Display Elements
39
Table 23: Signal Evaluation Per Channel, Control Status 0
39
Table 24: Signal Evaluation Per Channel, Control Status 1
39
Diagnostics Via Process Image
40
Using in Safety Related Applications
41
Important Notes
41
Connection for the I/O Module to Safety Switching Devices or F I/O Modules
43
General Structure of a Potential Group
43
Figure 14: Setting up a Potential Group (Example)
43
Table 25: Supply or Filter Modules for Setting up a Potential Group
43
Examples of Connection
44
Figure 15: Two-Channel Single-Pole Disconnection (Example)
44
Figure 16: Two-Channel Double-Pole Disconnection (Example)
45
Use in Hazardous Environments
46
Marking Configuration Examples
47
Marking for Europe According to ATEX and Iecex
47
Figure 17: Marking Example According to ATEX and Iecex
47
Figure 18: Text Detail - Marking Example According to ATEX and Iecex
47
Table 26: Description of Marking Example According to ATEX and Iecex
48
Figure 19: Marking Example for Approved Ex I I/O Module According to ATEX and Iecex
49
Figure 20: Text Detail - Marking Example for Approved Ex I I/O Module According to ATEX and Iecex
49
Table 27: Description of Marking Example for Approved Ex I I/O Module According to ATEX and Iecex
50
Marking for the United States of America (NEC) and Canada (CEC)
51
Figure 21: Marking Example According to NEC
51
Figure 22: Text Detail - Marking Example According to NEC 500
51
Table 28: Description of Marking Example According to NEC 500
51
Figure 23: Text Detail - Marking Example for Approved
52
Figure 24: Text Detail - Marking Example for Approved
52
Table 29: Description of Marking Example for Approved
52
Table 30: Description of Marking Example for Approved
52
Figure 25: Text Detail - Marking Example for Approved
53
Table 31: Description of Marking Example for Approved
53
Installation Regulations
54
Special Notes Regarding Explosion Protection
54
Special Notes Regarding ANSI/ISA Ex
56
List of Figures
57
List of Tables
58
Advertisement
Advertisement
Related Products
WAGO WAGO-I/O-SYSTEM 750-508
WAGO WAGO-I/O-SYSTEM 750-506
WAGO 750-502
WAGO 750-509
WAGO 750-506 Series
WAGO 750-506/000-800
WAGO 750-564
WAGO 750-557/040-000
WAGO 750-563/040-000
WAGO 750-535/040-000
WAGO Categories
I/O Systems
Control Unit
Power Supply
Switch
Controller
More WAGO Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL