WAGO -TO-PASS 761 Manual

WAGO -TO-PASS 761 Manual

Telecontrol module for fault detection/indication, monitoring and remote control, telecontrol module compact, web
Hide thumbs Also See for WAGO-TO-PASS 761:
Table of Contents

Advertisement

Quick Links

Manual
WAGO-TO-PASS® 761
Telecontrol Module Compact, Web
761-112
Telecontrol module for fault detection/indication,
monitoring and remote control
Version 2.0.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WAGO-TO-PASS 761 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for WAGO WAGO-TO-PASS 761

  • Page 1 Manual WAGO-TO-PASS® 761 Telecontrol Module Compact, Web 761-112 Telecontrol module for fault detection/indication, monitoring and remote control Version 2.0.0...
  • Page 2 WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web © 2013 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik GmbH & Co. KG Hansastraße 27 D-32423 Minden Phone: +49 (0) 571/8 87 – 0 Fax: +49 (0) 571/8 87 – 1 69 E-Mail: info@wago.com...
  • Page 3: Table Of Contents

    Shielding ..................... 21 3.4.4.1 General ................... 21 3.4.4.2 Bus Lines ..................21 3.4.4.3 Signal Lines ................... 21 3.4.4.4 WAGO Shield Connecting System ..........22 3.4.5 Digital Inputs ..................23 3.4.6 Counter Inputs ..................24 3.4.7 Digital Outputs ................... 25 3.4.8 Serial Interface to PC................
  • Page 4 Table of Contents WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 3.6.7 Digital Outputs ................... 29 Approvals ....................30 Standards and Guidelines ................ 30 Mounting ..................... 31 ® Mounting the TO-PASS telecontrol module to the DIN rail ....31 ® Removing the TO-PASS telecontrol module from the DIN rail ....
  • Page 5 WAGO-TO-PASS® 761 Table of Contents 761-112 Telecontrol Module Compact, Web Diagnostics ....................77 Test Inputs and Outputs ................77 Testing the Counter Inputs ..............78 Testing the Connection ................79 Testing the Modem ................. 80 ® WAGO TO-PASS Web ................81 Setting Parameters ...................
  • Page 6: Notes About This Documentation

    Manual by third parties that violate pertinent copyright provisions is prohibited. Reproduction, translation, electronic and phototechnical filing/archiving (e.g., photocopying) as well as any amendments require the written consent of WAGO Kontakttechnik GmbH & Co. KG, Minden, Germany. Non-observance will involve the right to assert damage claims. Manual...
  • Page 7: Symbols

    WAGO-TO-PASS® 761 Notes about this Documentation 761-112 Telecontrol Module Compact, Web Symbols Personal Injury! Indicates a high-risk, imminently hazardous situation which, if not avoided, will result in death or serious injury. Personal Injury Caused by Electric Current! Indicates a high-risk, imminently hazardous situation which, if not avoided, will result in death or serious injury.
  • Page 8 Notes about this Documentation WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Additional Information: Refers to additional information which is not an integral part of this documentation (e.g., the Internet). Manual Version 2.0.0...
  • Page 9: Number Notation

    WAGO-TO-PASS® 761 Notes about this Documentation 761-112 Telecontrol Module Compact, Web Number Notation Table 1: Number notation Number code Example Note Decimal Normal notation Hexadecimal 0x64 C notation Binary '100' In quotation marks, nibble separated with '0110.0100' dots (.) Font Conventions...
  • Page 10: Important Notes

    2.1.1 Subject to Changes WAGO Kontakttechnik GmbH & Co. KG reserves the right to provide for any alterations or modifications that serve to increase the efficiency of technical progress. WAGO Kontakttechnik GmbH & Co. KG owns all rights arising from the granting of patents or from the legal protection of utility patents.
  • Page 11: Disclaimer

    GPL. According to Section 3b of GPL, we offer you the source code. You can obtain the source code with licensing terms of the Open Source software from WAGO Kontakttechnik GmbH & Co. KG on request. Send your request to support@wago.com with the subject "Open Source TO-PASS Compact".
  • Page 12: Safety Advice (Precautions)

    Important Notes WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Safety Advice (Precautions) For installing and operating purposes of the relevant device to your system the following safety precautions shall be observed: Do not work on components while energized! All power sources to the device shall be switched off prior to performing any installation, repair or maintenance work.
  • Page 13 WAGO-TO-PASS® 761 Important Notes 761-112 Telecontrol Module Compact, Web Please note the following information about FCC Part 15! FCC Part 15.19 This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: 1. this device may not cause harmful interference, and 2.
  • Page 14 Important Notes WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Protect the components against materials having seeping and insulating properties! The components are not resistant to materials having seeping and insulating properties such as: aerosols, silicones and triglycerides (found in some hand creams).
  • Page 15: Device Description

    Please note that one SIM card is required to operate each TO-PASS telecontrol module and may be obtained from typical service providers such as T-Mobile, VODAFONE or EPlus. WAGO Kontakttechnik GmbH & Co. K.G. is prepared to assist with the selection of the most cost-effective tariff for your application. ®...
  • Page 16: Table 3: Overview Of Functions

    Device Description WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Table 3: Overview of functions Functionality FW 2.20 FW 2.31 FW 2.32 FW 2.33 Module name length 8 characters*) 16 characters*) 16 characters*) 16 characters*) (Identity) “Prepaid” request Always active Can be de-...
  • Page 17: View

    WAGO-TO-PASS® 761 Device Description 761-112 Telecontrol Module Compact, Web View Figure 1: Front view Position Description SIM Card insert Antenna connection Statusindication PC interface Connecting terminals for the supply, inputs and outputs Manual Version 2.0.0...
  • Page 18: Connectors

    Device Description WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Connectors 3.4.1 Antenna The screw connector (SMA socket) for the GSM antenna is located at the top of the housing. Figure 2: Antenna connection Observe the maximum length of the antenna cable!
  • Page 19: Operating Voltage

    WAGO-TO-PASS® 761 Device Description 761-112 Telecontrol Module Compact, Web 3.4.2 Operating Voltage Use SELV/PELV power source only! ® The TO-PASS telecontrol module must only be powered from a PELV (Protective Extra Low Voltage) or SELV (Safety Extra Low Voltage) power source complying with the limited power source (LPS) requirements per DIN EN 60950-1.
  • Page 20: Grounding

    The separate grounding of the carrier rail can be easily set up with the aid of the WAGO ground wire terminals. Table 5: WAGO ground wire terminals Item No. Description 283-609 1-conductor ground (earth) terminal block make an automatic contact to the carrier rail;...
  • Page 21: Shielding

    Higher shielding performance is achieved via low-impedance connection between shield and ground. To achieve this, connect the shield over a large surface area, e.g., WAGO shield connecting system. This is especially recommended for large- scale systems where equalizing current or high impulse-type currents caused by atmospheric discharge may occur.
  • Page 22: Wago Shield Connecting System

    3.4.4.4 WAGO Shield Connecting System The WAGO shield connecting system consists of shield clamping saddles, busbars and various mounting carriers to enable a wide variety of setups. For more information on this, refer to the "Accessories" section of the main catalog.
  • Page 23: Digital Inputs

    WAGO-TO-PASS® 761 Device Description 761-112 Telecontrol Module Compact, Web 3.4.5 Digital Inputs Only connect SELV/PELV voltages! Only SELV/PELV voltages shall be connected to the device terminals. Table 6: Terminal assignment for digital inputs Figure 5: Terminal assignment for digital inputs...
  • Page 24: Counter Inputs

    Device Description WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 3.4.6 Counter Inputs Only connect SELV/PELV voltages! Only SELV/PELV voltages shall be connected to the device terminals. Digital inputs D1 … D4 can be configured as counter inputs. Table 7: Counter input pin assignments...
  • Page 25: Digital Outputs

    WAGO-TO-PASS® 761 Device Description 761-112 Telecontrol Module Compact, Web 3.4.7 Digital Outputs Only connect SELV/PELV voltages! Only SELV/PELV voltages shall be connected to the device terminals. Table 8: Terminal assignment for digital outputs Figure 7: Terminal assignment for digital outputs...
  • Page 26: Serial Interface To Pc

    Device Description WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 3.4.8 Serial Interface to PC Table 9: Serial interface to the PC Description Not assigned Not assigned Not assigned Not assigned Figure 8: Serial interface to the PC Not assigned and MODBUS interface...
  • Page 27: Display Elements

    WAGO-TO-PASS® 761 Device Description 761-112 Telecontrol Module Compact, Web Display Elements Table 11: Display Elements Busy Description Green 0.5 Hz Ready to operate blinking Communication via RS232 Green interface Green 1 Hz Firmware update blinking GSM modem is activated Initialization (takes approx.
  • Page 28: Technical Data

    -40 °C ... +85 °C Type of mounting DIN 35 rail Degree of protection IP 20 Wire connection Terminal strips (WAGO 250 Series) with push-wire connection Cross section 0,5 mm² … 1,0 mm² AWG 22 … AWG 14 „sol“ Stripped length 9 mm …...
  • Page 29: Gsm Communication

    WAGO-TO-PASS® 761 Device Description 761-112 Telecontrol Module Compact, Web 3.6.4 GSM Communication Table 15: Technical Data Communication Number of recipients Recipient types PC, SMS, e-mail, phone, fax Communication GSM quad-band Communication types SMS (bidirectional), telecommunication dial-up connection (CSD), GPRS connection to Internet 3.6.5...
  • Page 30: Approvals

    Device Description WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Approvals The following approvals have been granted to 761-112 telecontrol modules: Conformity Marking UL508 R&TTE Complaint with 1999/5/EG directive (per Article 3.2) RoHS Device complies with European RoHS directive. Verification per FCC 15b...
  • Page 31: Mounting

    IP20 degree of protection ® The protection class of the TO-PASS telecontrol module is IP 20. For this reason, WAGO Kontakttechnik GmbH & Co. KG recommends mounting in a housing or in a switching cabinet. Ambient temperature -20 °C to +70 °C ®...
  • Page 32: Removing The To-Pass ® Telecontrol Module From The Din Rail

    Mounting WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web ® Removing the TO-PASS telecontrol module from the DIN rail ® Figure 11: Removing the TO-PASS telecontrol module from the DIN rail ® Press the undersurface against the lower DIN rail edge until the TO-PASS telecontrol module is no longer locked in place.
  • Page 33: Connect Devices

    If more than one conductor must be routed to one connection, these must be connected in an up-circuit wiring assembly, for example using WAGO feed- through terminals. Terminate both solid and ferruled conductors without actuation by simply pushing them in.
  • Page 34: Connection Examples

    Connect Devices WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Connection Examples Connect the shield connection to the DIN rail! ® The shield connection of the TO-PASS telecontrol module (shield, terminal 38) must be connected to the DIN rail. The DIN rail must have a low-impedance ground (see section "Connections"...
  • Page 35: Counter Inputs

    WAGO-TO-PASS® 761 Connect Devices 761-112 Telecontrol Module Compact, Web 5.2.2 Counter Inputs Only connect SELV/PELV voltages! Only SELV/PELV voltages shall be connected to the device terminals. Connect shielding! Shielded cables are recommended for the counter inputs. When using shielded cables, the shield must be routed to the grounded DIN rail (see Section "Connections"...
  • Page 36: Digital Outputs

    Connect Devices WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 5.2.3 Digital Outputs Only connect SELV/PELV voltages! Only SELV/PELV voltages shall be connected to the device terminals. Figure 14: Connection example for a relay at DO1 output Manual Version 2.0.0...
  • Page 37: Commissioning

    Select the CD drive in which you have placed the CD with the operating software. Start the "WAGO TO-PASS_SETUP(2.17).EXE" program, or a newer version in the main directory on the CD. Follow the menu prompting to choose a default installation path.
  • Page 38: Starting The To-Pass Telecontrol Module

    Commissioning WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web ® Starting the TO-PASS Telecontrol Module Do not switch on yet! ® Do not switch on the TO-PASS telecontrol module until you are prompted to do so; do not insert the SIM card for this procedure.
  • Page 39 WAGO-TO-PASS® 761 Commissioning 761-112 Telecontrol Module Compact, Web When generating a new configuration file, select the firmware version for the device that implements the required functionality as the first version in the Function selection field. The device versions, along with the associated enabling firmware indices are displayed to make selection easier.
  • Page 40: Parameterizing

    Commissioning WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 6.2.1 Parameterizing General Settings Select the menu item File Settings for making general settings, such as type of > ® connection, interface or language for the TO-PASS operating interface. Figure 15: General settings...
  • Page 41 WAGO-TO-PASS® 761 Commissioning 761-112 Telecontrol Module Compact, Web Table 19: General settings Interface COM1 ... COMx Here, select the serial interface where the communication cable is connected with a RS-232 connection. Language ® English / Select the langauge for the TO-PASS operator interface here.
  • Page 42: Reading Parameters From The Module

    Commissioning WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Reading Parameters from the Module ® After you have set the type of connection for communicating with the TO-PASS telecontrol module, you are then able to read out the parameters of the connected module.
  • Page 43: Identity

    WAGO-TO-PASS® 761 Commissioning 761-112 Telecontrol Module Compact, Web Identity ® Select the TO-PASS telecontrol module to be configured from the project tree; under it, select the Identity option. On the right side you will find the selection field for the function, the display field for the name, the input field for the telephone number, buttons and input fields for the PIN, roaming and prepaid and the input field for the alarm counter.
  • Page 44: Table 20: Configuring The Identity

    Commissioning WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Table 20: Configuring the identity General Function selection You can redifine the firmware version in this selection field, that is to say the available scope of functions (e.g., to ensure compatibility with devices already in use).
  • Page 45: Addresses

    WAGO-TO-PASS® 761 Commissioning 761-112 Telecontrol Module Compact, Web Addresses ® The TO-PASS telecontrol module can communicate with a maximum of four ® transmitters/receivers via GSM. Messages are sent by the TO-PASS telecontrol module as SMS; however, they can also be sent as an e-mail, fax or voice mail, as defined in configuration.
  • Page 46: Table 21: Configuring The Addresses

    Commissioning WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Table 21: Configuring the addresses Phone/Fax/Mail Address 1 ... Enter the target addresses in these fields: Address 4 Transmission as SMS: Enter the mobile phone number of the recipient. Click the button [T2T] when the SMS recipient is also a TO- ®...
  • Page 47 In this field enter the port for the Web portal (e.g., "80" for most http applications) Script (value), In this field enter the script name for data transmission, for for transmitting test purposes, e.g., "wago/saveTO-PASS.php". alarms and status The "saveTO-PASS.php" script checks the version messages indications from transmitted data and forwards this information to the processing script.
  • Page 48: Configuring Inputs And Outputs

    Commissioning WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Configuring Inputs and Outputs Digital Inputs ® Select your TO-PASS telecontrol module from the left side of the project tree using the identifier. Select the input to be configured under Digital Inputs.
  • Page 49: Figure 19: Configuring Digital Inputs 5

    WAGO-TO-PASS® 761 Commissioning 761-112 Telecontrol Module Compact, Web Figure 19: Configuring digital inputs 5 … 8 (when provided) Table 22: Configuring of digital inputs Counters (only for digital inputs 1 … 4) Counters Check this box to use the selected digital input as a counter input.
  • Page 50 Commissioning WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Table 22: Configuring of digital inputs Alarm settings First value Check this box to have a message sent when the first limit is exceeded for upward counting or when the first lower limit is violated for downward counting.
  • Page 51 WAGO-TO-PASS® 761 Commissioning 761-112 Telecontrol Module Compact, Web Table 22: Configuring of digital inputs Deactivation text In this field enter the text to be contained in the message transmitted when the digital input has been reset, or when the counted value has violated the second limit.
  • Page 52: Multiplex Input

    Commissioning WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Multiplex Input You can configure digital inputs DI1 ... DI4 as multiplex inputs. These four inputs will then additionally be read in as a combination and intepreted as a binary number. The following applies in this case:...
  • Page 53: Multiplex Settings

    WAGO-TO-PASS® 761 Commissioning 761-112 Telecontrol Module Compact, Web 6.10 Multiplex Settings ® Select your TO-PASS telecontrol module from the left side of the project tree using the identifier. Select the Multiplex Settings option under Multiplex Input. The buttons for enabling multiplex operation and the selection of the recipients of the analog values to be transmitted are provided on the right side.
  • Page 54: Multiplex Alarm Text

    Commissioning WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 6.10.1.1 Multiplex Alarm Text ® Select your TO-PASS telecontrol module from the left side of the project tree using the identifier. Select the Multiplex Table option under the Multiplex Input entry. The input fields for the alarm texts pertaining to the 16 statuses are provided on the right side.
  • Page 55: Digital Outputs

    WAGO-TO-PASS® 761 Commissioning 761-112 Telecontrol Module Compact, Web 6.10.2 Digital Outputs ® Select your TO-PASS telecontrol module from the left side of the project tree using the identifier. Select the output to be configured under the entry Digital Outputs. The parameters of the output are given on the right side. The input fields are...
  • Page 56: Configuring Error Detectors

    Commissioning WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 6.11 Configuring Error Detectors ® The TO-PASS telecontrol module can transmit error messages to a maximum of four recipients. The recipients are informed either directly one after another or (if configured) after expiration of the time delay for acknowledgment. The message ®...
  • Page 57: Acknowledgement

    WAGO-TO-PASS® 761 Commissioning 761-112 Telecontrol Module Compact, Web 6.11.3 Acknowledgement Acknowledgment is the confirmation that a message has actually been sent to the ® recipient. Select the TO-PASS telecontrol module from the project tree using the identifier. Select the entry Acknowledgment under the option Special Functions.
  • Page 58: Transmission Repeat Times

    Commissioning WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 6.11.4 Transmission Repeat Times ® Select the TO-PASS telecontrol module from the project tree using the identifier. Select the entry Repeat times under the option Special Functions. The input fields for the Web interval, the Web outputs and the SMS interval and buttons for target addresses are located on the right side.
  • Page 59: Table 27: Configuring The Transmission Repeat Times

    WAGO-TO-PASS® 761 Commissioning 761-112 Telecontrol Module Compact, Web Table 27: Configuring the transmission repeat times Web settings Web interval In this field enter the cycle time in minutes to define the ® intervals that the TO-PASS telecontrol module is to send data to the Internet.
  • Page 60 Commissioning WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Table 27: Configuring the transmission repeat times SMS Settings SMS interval Here, enter the cycle time in minutes to define the intervals ® that the TO-PASS telecontrol module is to send data to the addresses defined under Address.
  • Page 61: Time Adjustment

    WAGO-TO-PASS® 761 Commissioning 761-112 Telecontrol Module Compact, Web 6.12 Time Adjustment ® Select the TO-PASS telecontrol module from the project tree using the identifier. Select the entry Acknowledgment under the option Time setting. The buttons for various settings pertaining to time adjustment are located on the right side.
  • Page 62: Writing Parameters To The Module

    Commissioning WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 6.13 Writing Parameters to the Module ® After you have adapted all parameters for the TO-PASS telecontrol module to your requirements, you have to write the parameters to the connected module. Select the menu option Edit > Write Parameters. The software then writes all ®...
  • Page 63: Operation

    WAGO-TO-PASS® 761 Commissioning 761-112 Telecontrol Module Compact, Web 6.13.1 Operation 6.14 Remote Query of Process Values ® The TO-PASS telecontrol module offers two options for remote inquiry of the process values available: • Query via SMS ® • Query with the TO-PASS...
  • Page 64: Remote Polling Via Sms

    Commissioning WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 6.14.1 Remote Polling via SMS For remote polling via SMS, send an SMS containing the text "State" to the TO- ® PASS telecontrol module. ® The TO-PASS telecontrol module responds promptly with an SMS to your mobile phone containing all of the current process values.
  • Page 65: Table 31: Counter Status

    WAGO-TO-PASS® 761 Commissioning 761-112 Telecontrol Module Compact, Web Table 31: Counter status Status Explanation Digital input not configured as a counter. e:ZW Counter is active: Counter value. d:ZW Counter is not active: Counter value. o:ZW Counter overflow: Counter vlaue. r:ZW Counter has been reset: Counter value.
  • Page 66: Remote Polling Using The To-Pass Operating Program

    Remote Polling using the TO-PASS® Operating Program WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web ® Remote Polling using the TO-PASS Operating Program ® To display the process values with the TO-PASS operator program, select the menu item Visualization > Process values. The program establishes a link to the ®...
  • Page 67: Inputs/Outputs

    WAGO-TO-PASS® 761 Remote Polling using the TO-PASS® Operating Program 761-112 Telecontrol Module Compact, Web 7.1.1.1 Inputs/Outputs Press the [I/O] button to display the process values of the inputs and outputs. The process values displayed are valid if the on-line display is green.
  • Page 68: Counters

    Remote Polling using the TO-PASS® Operating Program WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 7.1.1.2 Counters To display the counter process values, click the [Counter] button (possible only when inputs have been configured as counters). The process values displayed are valid when the on-line indicator is highlighted in green.
  • Page 69: Telecontrol

    WAGO-TO-PASS® 761 Remote Polling using the TO-PASS® Operating Program 761-112 Telecontrol Module Compact, Web 7.1.2 Telecontrol ® TO-PASS telecontrol modules offer the option of influencing a process remotely with the help of their analog and digital outputs. There are two methods available: •...
  • Page 70: Telecontrol Via Sms

    Remote Polling using the TO-PASS® Operating Program WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 7.1.3 Telecontrol via SMS 7.1.4 Setting or Resetting a Digital Output To set or reset a digital output, send an SMS with the text that is entered under ®...
  • Page 71: Changing The Counter Value Or Status

    WAGO-TO-PASS® 761 Remote Polling using the TO-PASS® Operating Program 761-112 Telecontrol Module Compact, Web 7.1.4.1 Changing the Counter Value or Status To change the value or the status of a counter, send an SMS containing the text "Counter" and the corresponding control commands (more than one can be sent) ®...
  • Page 72: Telecontrol With The To-Pass

    Remote Polling using the TO-PASS® Operating Program WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web ® 7.1.4.2 Telecontrol with the TO-PASS Operator Program ® To display the process values with the TO-PASS operator program, select the menu item Visualization > Process values. The program establishes a link to the ®...
  • Page 73: Inputs/Outputs

    WAGO-TO-PASS® 761 Remote Polling using the TO-PASS® Operating Program 761-112 Telecontrol Module Compact, Web 7.1.5 Inputs/Outputs Press the [I/O] button to display the process values of the inputs and outputs. The process values displayed are valid if the on-line display is green.
  • Page 74: Counters

    Remote Polling using the TO-PASS® Operating Program WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 7.1.5.1 Counters To display the counter process values, click the [Counter] button (possible only when inputs have been configured as counters). The process values displayed are valid when the on-line indicator is highlighted in green.
  • Page 75: Acknowledging Error Messages

    WAGO-TO-PASS® 761 Remote Polling using the TO-PASS® Operating Program 761-112 Telecontrol Module Compact, Web Acknowledging Error Messages If a waiting time not equal to 0 has been set for the acknowledgment of error ® messages, the TO-PASS telecontrol modules expects an acknowledgment of error messages from the recipient.
  • Page 76: Switching To Standby

    Remote Polling using the TO-PASS® Operating Program WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 7.2.1 Switching to Standby Standby authorization Switching standby on and off is only possible by subscribers whose telephone number has been entered in the address list! Using the "Standby"...
  • Page 77: Diagnostics

    WAGO-TO-PASS® 761 Diagnostics 761-112 Telecontrol Module Compact, Web Diagnostics Test Inputs and Outputs To test the inputs and outputs select the menu option Controller > Test I/O. The following window is displayed: Figure 30: Test inputs and outputs The process values of the inputs are displayed in the upper area and the process values of the outputs are displayed in the lower area.
  • Page 78: Testing The Counter Inputs

    Diagnostics WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Testing the Counter Inputs To test the counter inputs, select the menu item Edit > Test counters. Figure 31: Testing counters The counter statuses are shown at the top of the window, while the counter values, the starting and end values and the limits are shown at the bottom.
  • Page 79: Testing The Connection

    WAGO-TO-PASS® 761 Diagnostics 761-112 Telecontrol Module Compact, Web Testing the Connection Direct serial link required ® The connection may only be tested with a direct serial link to the TO-PASS telecontrol module. To test the connection, select the menu option Edit > Test SMS/GPRS. The...
  • Page 80: Testing The Modem

    Diagnostics WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Testing the Modem Direct serial link required ® The modem test may only be performed with a direct serial link to the TO-PASS telecontrol module. To test the mode, select the menu item Modem > Test.
  • Page 81: Wago To-Pass Web

    To do this, enter "www.to-pass.com" as the Host address and the value "80" as the Host port. Enter "wago/saveTO-PASS.php" as the script name under Script (Values) and/or under Script (Logger). Enter the information for your SIM card provider for APN access, user name and password (see also Section “Parameter setting”...
  • Page 82: Http Request

    ® The HTTP method "POST" transmits the process image of the TO-PASS ® telecontrol module to the Internet to the WAGO TO-PASS portal. A data set consists of form data in the context of the request (header and data string).
  • Page 83: Data Sets

    WAGO-TO-PASS® 761 WAGO TO-PASS® Web 761-112 Telecontrol Module Compact, Web Data Sets To distinguish the structure of the incoming data sets, the new data sets are marked with a version variable. The variable is structured as “xx.yy”, while “xx” is changed for major modifications and “yy” is changed for minor extensions.
  • Page 84: Value Script Fw 2.20 (Standard)

    Value Script FW 2.20 (Standard) WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Value Script FW 2.20 (Standard) Table 34: Data format for value script FW 2.20 (Standard) Index Variable Contents Format Identity Identity[8];Serial number[5] Parameter Cycle time[4];Provider[5];Alarm counter[2] Date, time YY/MM/DD,hh:mm:ss;...
  • Page 85: Example Of Value Script Fw 2.20 (Standard)

    WAGO-TO-PASS® 761 Value Script FW 2.20 (Standard) 761-112 Telecontrol Module Compact, Web 10.1.1 Example of Value Script FW 2.20 (Standard) To improve readability, line breaks have been inserted. ID=TO-PASS;12345 &PA=0000;home ;99 &TI=11/05/05,14:34:21 &D1=1;0&D2=0;0&D3=0;0&D4=0;0&D5=0;0&D6=0;0&D7=0;0&D8=0;0 &A1=+00.00;mA;0&A2=+00.00;mA;0&A3=+00.00;mA;0&A4=+00.00;mA;0 &A5=+00.00;mA;0&A6=+00.00;mA;0&A7=+00.00;mA;0&A8=+00.00;mA;0 &US=Hello &PO=123155.000,5217.9742N,00855.2710E,4.4,74.9,2,214.30,6.0,3.2, 110505.00 Manual Version 2.0.0...
  • Page 86: Value Script Fw 2.31 (Extended)

    Value Script FW 2.20 (Standard) WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 10.2 Value Script FW 2.31 (Extended) Due to extended functionalities, the value script has been extended to include a version designation ("01.01") as well as supply voltage, output values and GPS information.
  • Page 87: Table 36: Meaning Of Flag

    WAGO-TO-PASS® 761 Value Script FW 2.20 (Standard) 761-112 Telecontrol Module Compact, Web Table 36: Meaning of flag Flag 1 Flag 2 Flag 3 Flag 4 Flag 5 Flag 6 Flag 7 Flag 8 Flag 1 0: GPS has not been started.
  • Page 88: Example Of Value Script Fw 2.31 (Extended)

    Value Script FW 2.20 (Standard) WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 10.2.1 Example of Value Script FW 2.31 (Extended) To improve readability, line breaks have been inserted. ID=TO-PASS(Ext);12345 &SV=01.01 &PA=0000;home ;99 &TI=11/05/05,12:19:51 &D1=0;0&D2=0;0&D3=0;0&D4=0;0&D5=0;0&D6=0;0&D7=0;0&D8=0;0 &A1=+00.00;mA;0&A2=+00.00;mA;0&A3=+00.00;mA;0&A4=+00.00;mA;0 &A5=+00.00;mA;0&A6=+00.00;mA;0&A7=+00.00;mA;0&A8=+00.00;mA;0 &VS=+25.16;V(Uv);0 DO0000 &AO=+0000;mA;+0400;mA &US=Hello &PO=101550.000,5217.9860N,00855.2699E,4.4,51.5,2,309.35,3.7,2.0,11...
  • Page 89: Value Script Fw 2.33 (Counter Inputs)

    WAGO-TO-PASS® 761 Value Script FW 2.20 (Standard) 761-112 Telecontrol Module Compact, Web 10.2.1.1 Value Script FW 2.33 (Counter Inputs) The counter inputs have resulted in counter data, signal quality and an indicator being added to the display for the value script ("SV=02.00") and to an update of the MODBUS registers and analog outputs.
  • Page 90: Table 38: Alarm Status

    Value Script FW 2.20 (Standard) WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web The counter status shows the last change that has occurred since the last value script transmission, or after a system start (independent of the SMS and logger status).
  • Page 91: Example Of Value Script Fw 2.33 (Counter Inputs)

    WAGO-TO-PASS® 761 Value Script FW 2.20 (Standard) 761-112 Telecontrol Module Compact, Web 10.2.1.2 Example of Value Script FW 2.33 (Counter Inputs) To improve readability, line breaks have been inserted. ID=TO-PASS(Cnt);12345 &SV=02.00 &PA=0000;home ;99 &TI=11/05/05,12:19:51 &D1=0;0&D2=0;0&D3=0;0&D4=0;0&D5=0;0&D6=0;0&D7=0;0&D8=0;0 &A1=+00.00;mA;0&A2=+00.00;mA;0&A3=+00.00;mA;0&A4=+00.00;mA;0 &A5=+00.00;mA;0&A6=+00.00;mA;0&A7=+00.00;mA;0&A8=+00.00;mA;0 &VS=+25.16;V(Uv);0 DO0000 &AO=+00.00;mA;+04.00;mA &C1=0;0;0...
  • Page 92: Logger Script

    Value Script FW 2.20 (Standard) WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 10.2.2 Logger Script Data transmission to the logger script is activated via cyclical transmission repetitions (Web interval). Data packet information contains the logger's values that have not been acknowledged yet.
  • Page 93: Logger Script Standard

    WAGO-TO-PASS® 761 Value Script FW 2.20 (Standard) 761-112 Telecontrol Module Compact, Web 10.2.2.1 Logger Script Standard In the standard format, 10 logger entries are transmitted in a packet. Each entry consists of a compressed data set of 14 binary bytes, which are attached to the hexadecimal character string of the variable.
  • Page 94: Example For Logger Script Standard

    Value Script FW 2.20 (Standard) WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 10.2.3 Example for Logger Script Standard To improve readability, line breaks have been inserted. ID=TO-PASS;12345 &PA=0005;home ;99 &TI=11/05/05,14:36:11 &LO= 092D4AD100000000000000000000 562D4AD123000000000000000000 3F2D4AD12A000000000000000000 562D4AD137000000000000000000 562D4AD159000000000000000000 562D4AD164000000000000000000 3F2D4AD169000000000000000000 562D4AD19A000000000000000000 3F2D4AD1A9000000000000000000...
  • Page 95: Logger Script Extension

    WAGO-TO-PASS® 761 Value Script FW 2.20 (Standard) 761-112 Telecontrol Module Compact, Web 10.2.3.1 Logger Script Extension The logger script has been updated due to extended functionalities. The “02.00” version designation has been assigned due to major modifications. Table 41: Data format for logger script FW 2.31 (extended)
  • Page 96: Data Format For Liox Variable

    Value Script FW 2.20 (Standard) WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web 10.2.4 Data Format for LIOx Variable Table 42: Data format for logger script FW 2.31 (extended), Variable LIOx Index Contents Format Message counter Message counter[4]; Event (cyclic logger) Event[2];...
  • Page 97: Example For Logger Script Extension

    WAGO-TO-PASS® 761 Value Script FW 2.20 (Standard) 761-112 Telecontrol Module Compact, Web 10.2.4.2 Example for Logger Script Extension To improve readability, line breaks have been inserted. ID=TO-PASS(Ext);12345 &LV=02.00 &PA=0005;home ;99 &TI=11/05/05,08:38:22 &LIO1=0019;09;11/05/05,08:33:44;00;000;000;000;000;000;000;000;000 ;C4A;0;000;000 &LPD1=10;08/01/01,06:33:35;274;0;0;N;0;0;W;00;0;0;0;0;0;0;0 &LIO2=001A;3F;11/05/05,08:34:02;00;000;000;000;000;000;000;000;000 ;BA2;0;000;000 &LPD2=10;08/01/01,06:33:55;274;0;0;N;0;0;W;00;0;0;0;0;0;0;0 &LIO3=001B;56;11/05/05,08:34:26;00;000;000;000;000;000;000;000;000 ;B89;0;000;000 &LPD3=C0;11/05/05,06:34:25;276;C41;2600;N;216;1621;E;0C;4D34;3;26A F;21;11;7;0...
  • Page 98 Value Script FW 2.20 (Standard) WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web The calculations for longitudes/latitudes (see below) refer to the format as transmitted in the NMEA data (ccmm.mmmm with cc = degree, mm.mmmm = Angular minute). The cc.mm format is used to indicate the direction (also according to NMEA definition).
  • Page 99: Logger Script Fw 2.33 (Counter Inputs)

    WAGO-TO-PASS® 761 Value Script FW 2.20 (Standard) 761-112 Telecontrol Module Compact, Web 10.2.4.2.1 Logger Script FW 2.33 (Counter Inputs) The counter inputs have resulted in counter data and an indicator being added to the display for non-set time (operating hours) to the logger script ("LV=02.01").
  • Page 100: Table 46: Number Of Data Sets

    Value Script FW 2.20 (Standard) WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Table 46: Number of data sets Script Version Counter &LO &LIO &LPD &LCD FW 2.20 FW 2.31 FW 2.31 FW 2.33 FW 2.33 FW 2.33 FW 2.33 Example: navigation of level 3.
  • Page 101: Time Request Script Fw 2.33

    WAGO-TO-PASS® 761 Value Script FW 2.20 (Standard) 761-112 Telecontrol Module Compact, Web 10.2.4.3 Time Request Script FW 2.33 If time adjustment is to take place via the Internet, a time request script is transmitted on system start in order to adjust the time when a reply is received.
  • Page 102: Http Response

    The data string must contain the following text: “Values stored” or “Values stored:YY/MM/DD,hh:mm:ss”. Date and time are optional and are required only if the time of the WAGO TO- ® PASS telecontrol module is to be set via the Web portal.
  • Page 103: Example Of Http Response

    WAGO-TO-PASS® 761 Value Script FW 2.20 (Standard) 761-112 Telecontrol Module Compact, Web 10.3.1.1 Example of HTTP Response The HTTP response consists of both header and data string, which are separated by an empty line (<CR><LF> = Carriage Return + Line Feed).
  • Page 104: List Of Figures

    Figure 2: Antenna connection ................18 Figure 3: Terminal assignment for operating voltage ........... 19 Figure 4: Example of the WAGO shield connecting system ........ 22 Figure 5: Terminal assignment for digital inputs ..........23 Figure 6: Counter input pin assignments ............... 24 Figure 7: Terminal assignment for digital outputs ..........
  • Page 105: List Of Tables

    Table 3: Overview of functions ................16 Table 4: Terminal assignment for operating voltage ..........19 Table 5: WAGO ground wire terminals ..............20 Table 6: Terminal assignment for digital inputs ........... 23 Table 7: Counter input pin assignments ..............24 Table 8: Terminal assignment for digital outputs ..........
  • Page 106 List of Tables WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Manual Version 2.0.0...
  • Page 107 WAGO-TO-PASS® 761 761-112 Telecontrol Module Compact, Web Manual Version 2.0.0...
  • Page 108 WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 • D-32385 Minden Hansastraße 27 • D-32423 Minden Phone: +49/5 71/8 87 – 0 Fax: +49/5 71/8 87 – 1 69 E-Mail: info@wago.com Internet: http://www.wago.com...

This manual is also suitable for:

761-112

Table of Contents