Mounting
Pos : 23.16 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/F eldbus koppler/M ontage_Befestigung auf Tragsc hienenadapter 767- xxxx_Fel dbus koppl er @ 7\mod_1268894150891_21.doc x @ 53374 @ 3 @ 1
5.4.2
Fastening the Fieldbus Coupler with Carrier Rail Adapter to
a Carrier Rail
In order to provide a clear representation, the carrier rail adapter in the figure
below is shown without the fieldbus coupler.
When mounting the fieldbus coupler to a carrier rail (DIN rail 35 x 7.5) using a
carrier rail adapter, proceed as follows:
1.
Disconnect the power supply from those devices on which you wish to
mount the fieldbus coupler.
2.
Set the fieldbus coupler onto the edge of the carrier rail (61) with the two
notches (60).
3.
Press the undersurface against the lower carrier rail edge until the latch (62)
locks in place.
Use end stops
When mounting the rail vertically or if shock or vibration loading should occur,
the use of end stops (item no.: 249-116 or 249-117) for stabilization is required.
Pos : 23.17 /Serie 767 ( WAGO-SPEED WAY)/Monti eren/F eldbus koppler/M ontage_Befestigung auf Tragsc hienenadapter 767- xxxx_Fel dbus koppl er - Bild @ 7\mod_1268905883023_21.doc x @ 53430 @ @ 1

Figure 11: Mounting the carrier rail adapter