In some cases, when testing the operation of an
extension port when connecting to a Cordless II,
Cordless Lite II, or PGD(2)-U10 ADP, a technician
may connect a line cord directly from an extension
port on the CD-8DLCA/CD-16DLCA Blade. Though
this is not the recommended connection, it can be
used to test these devices.
Should a direct connection of this type be made to the
base station of the Cordless II or Cordless Lite II, or
to a PGD(2)-U10 ADP, the line cord must be 2-wire
(1-pair). If a 2-pair wire is used, the system will
provide power to the unused pair. This can prevent
the cordless telephone from acquiring a link with the
base station or it can damage the PGD(2)-U10 ADP
or the SV8100 station card.
The recommended connection is to punch down 2
wires to the cross-connect block, then connect the
extension block to the RJ-61 connector on the Blade.
13.
Optional:
To wall mount the PGD(2)-U10 ADP, insert two wood screws 100mm
apart (3 15/16"). Leave 3mm (1/8") of the screw exposed. The screws
can be installed either vertical or horizontal, depending on which position
fits best for your location.

Figure 11-8 Installing the Screws