2.5
2.6
6 - 8
Blade Capacities
The universal architecture of the UNIVERGE SV8100/SV8300 provides
flexibility when installing blades. With the exception of the CD-CP00-US and
CC-CP00 blades, any blade can be installed in any slot.
System Capacities – Blades on page 2-9
System Capacity – Chassis on page 3-9
and the maximum capacities with various chassis configurations.
Powering Up the SV8100
2.6.1
Performing a Cold Start
This section describes the process for starting the system for the first
time or starting a system that has been turned off.
System software loaded from flash memory and the
customer data is erased from RAM memory.
To avoid extension and trunk renumbering, if certain
blades are recognized first, remove them from their
respective slots until the system has been reset. Then,
slot the blade cards in the correct order to retain the
proper system numbering (Use Program 10-03 prior to
performing a cold start to record the current slot
definitions.).
To perform a cold start:
1.
Turn the system power off.
2.
Once the system has powered down, push in and hold the
Load button.
3.
Turn the power switch back on to power the system back up.
With a multi-chassis system, turn on the Expansion Chassis
power supply, then the Controlling Chassis power supply.
4.
Continue holding the Load button for approximately three
seconds or until LED 2 starts flashing red.
5.
Release the Load button.
6.
When the system has completed reloading the software (two
minutes), the Status LED is flashing on the CD-CP00-US.