Table 3-14 Power Consumption - NEC Univerge SV8100 System Hardware Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100/SV8300
6.3
System Hardware Manual
VA @ 120V: Controlling Chassis=263 VA, Expansion Chassis=
263 VA, total 526 VA KWh @ AC Input I x 120V/1000: Controlling
Chassis=0.263 KWh, Expansion Chassis=0.263 KWh, total 0.526
KWh
BTU (KWh x 3413): Controlling Chassis=1795 BTU, Expansion
Chassis=1795 BTU, total 3590 BTU
Double Pole/Neutral Fusing
(power supply fuses are located at both the L and N
side).
6.2.2
Power Supply Consumption
Chassis
Controlling Chassis
Controlling Chassis + Expansion
Chassis
Controlling Chassis + 2 Expansion
Chassis
Controlling Chassis + 3 Expansion
Chassis
Environmental Conditions
6.3.1
Temperature and Humidity
Chassis, Telephones, 16LK, Console, ADA, APR
Operating Temperature: +32°F ~ +104°F (0°C ~ 40°C)
Recommended Long Term Temperature: -4°F ~ +140°F
(20°C ~ 60°C)
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 90% RH
Blades – PZ-BS10, PZ-BS11, CD-8DLCA, CD-16DLCA,
PZ-8DLCB
Operating Temperature: +32°F ~ +104
Recommended Long Term Temperature: -4°F ~ +140°F
(20°C ~ 60°C)

Table 3-14 Power Consumption

Maximum
RMS
Current
0.7 A
3.4 A
6.1 A
8.8 A
Issue 1.0
Watts Used
Watts Used
(Idle)
(Maximum)
40 w
45 w
160 w
225 w
280 w
405 w
400 w
585 w
o
o
o
F (0
C ~ 40
C)