Document Description

This document is a quick reference for the base SL 1100 KSU's connections, base default as well as cross reference for
which manual to refer to. This document is not intended to replace other SL 1100 manuals.
These instructions are for reference only. Do not install the system without first reading the Hardware & Features and
Specifications Manuals.

Performing a Cold Start (Initialization):

Note:
Before turning on power to the system for the first time it is a good practice to install all expansion cards and the
InMail Compact Flash card so that the system can Auto Detect them upon Cold Start.
If Expansion KSUs are installed turn the power on/off in order of Expansion KSU 2, Expansion KSU 1, and then
Main KSU.
1) Set the power switch to the off position.
2) Push in and hold the red Load button on the CPU.
3) Turn the power switch to the on position on the Main KSU.
4) Continue holding the Load button for approximately 3 seconds or until the status LED D5 starts to flash red.
5) Release the Load button.
6) When the system has completed reloading software (approximately 2 minutes) the Run LED is flashing blue on
the CPU and connected Multi-Line phones show Time & Date and Extension number.

Installing the Expansion Interface Cards:

• Each KSU can have up to two expansion cards.
• Expansion card include: IPWW-080E-B1 (8 Port Digital Station Card ESIU), IPWW-0008E-B1 (8 port Analog
Station Card SLIU), IP-WW-PRIU-C1 (PRI/T1 card).
• IP-WW-4COIDB-B1 (4 port analog Trunk Daughter Board Card) May only be mounted on the following cards
084M-B1 (KSU Mother Board), 080E-B1 (8 port ESIU), or 0008E-B1 (8 Port SLIU card) but not the PRIU-C1 card.
• KSU must be powered off before installing any of the above expansion cards.
- 3 -