NEC Univerge SV8100 System Hardware Manual page 236

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 1.0
2.2
2.3
5 - 2
To avoid damage, the chassis should not be placed on unstable surfaces.
Although it is recommended to install the blades with the system power off,
all blades can be installed hot, except for the following:
CC-CP00
PZ-BS10 and PZ-BS11
PZ-64IPLA and PZ-128IPLA
PZ-VM21
Surveying the Customer Site
In most cases, a survey of the customer site is necessary to determine the
proper placement of the Main Distribution Frame (MDF), the exact dimensions
of the area selected for the MDF, cabling requirements, and possible
Intermediate Distribution Frame (IDF) locations.
The information obtained at the customer site can permit the installer to
partially assemble the MDF before installation at the customer premise. This
can reduce the time spent installing at the customer site and reduce
downtime.
Selecting the Best Location for Proper Installation
2.3.1
Selecting the Chassis Installation Site
When selecting an installation site for the chassis, consider the
following conditions to ensure proper installation:
The chassis should not be located directly beneath pipes. Leaks or
condensation could damage the SV8300 system equipment.
The area where the chassis is located must be free of corrosive and
inflammable gases, excessive chemical or industrial dusts, and other
materials that could cause a hazard to personnel or to the proper
functioning of the equipment.
The operating ambient temperature and humidity must be within the
limits specified in
Chapter 3 System Specifications.
The operation of the system is virtually noiseless and allows wide
selection of installation sites. Take care to ensure the chassis or cabling
do not present a hazard to office traffic. To minimize cabling costs, a
centralized location must be chosen.
Locate the chassis at a site where a dedicated AC power source can be
easily accessed.
Connect the chassis to a dedicated AC receptacle that is not being
used for any other device.
UNIVERGE SV8100/SV8300
6.3 Environmental Conditions on page 2-30
Installing the SV8300 Chassis