NEC Univerge SV8100 System Hardware Manual page 156

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 1.0
6.4
3 - 22
Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 90% RH
Blades - CD-4LCA, PZ-4LCA, CD-8LCA, PZ-8LCE, CD-4COTB,
PZ-4COTF, CD-PRTA, CD-CCTA
Operating Temperature: +32°F ~ +104°F (0°C ~ 40°C)
Recommended Long Term Temperature: -4°F ~ +140°F
(20°C ~ 60°C)
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 20 ~ 90% RH
Door Box
Operating Temperature: -4°F ~ +104
Operating Humidity: 20 ~ 80% (non-condensing)
SV8300 Power Supply – MPS7101
Operating Temperature: +32°F ~ +104°F (0
Recommended Long Term Temperature: -4°F ~ 167
o
(-40
C ~ 75
Operating Humidity: 20 ~ 95% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 95% RH
Outside Line Types
The following outside lines can be used with the SV8300 system.
2-wire, Loop Start or Ground Start Trunks
2-wire, 2-way DID Lines (Dial Pulse or DTMF)
DID feature is not available for Europe and Australia market.
2-wire/4-wire, E&M Tie Lines (Type I or V, Dial Pulse, or DTMF)
Digital Trunk T1/FT1 (Loop Start, Ground Start, Tie Line (E&M), or DID
Signaling)
ISDN-BRI Trunks
ISDN-PRI Trunks
VoIP Trunks (Internet Protocols)
o
C)
UNIVERGE SV8100/SV8300
o
o
o
F (-20
C ~ 60
C
o
o
C ~ +40
C)
o
F
SV8300 System Specifications

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Univerge sv8300

Table of Contents