Issue 1.0
B
S
4
ATTERY
ECTION
There are two types of battery connection to provide battery life in the event of a
power failure, the internal battery and an external battery with CHS LARGE BATT
BOX.
4.1
4 - 42
C
ONNECTION
Installing the Internal Batteries
An internal battery source using two batteries can be installed using the
CHS2U BATT MTG KIT (mounting kit) and CHS2U BATT CABLE INT (internal
cabling).
CHS2U BATT MTG KIT (Backup time = 10 Minutes/24 Terminals)
1.
Ensure the chassis is powered down.
Ensure the CHS2U-US chassis is powered OFF.
2.
Disconnect AC power and grounding cable from rear of chassis.
3.
Remove screws from battery access panel on rear of chassis. Refer to
Figure 4-47 Removing Battery Access

Figure 4-47 Removing Battery Access Panel

UNIVERGE SV8100/SV8300
Panel.
Installing the SV8100 Chassis