Figure 11-1 Pgd(2)-U10 Adp; Table 11-1 Pgd(2)-U10 Adp Led Indications - NEC Univerge SV8100 System Hardware Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 1.0
2.2
2.3
11 - 2
The PGD(2)-U10 ADP connects to any available digital extension port. The
terminal connections made within the PGD(2)-U10 ADP and the jumper
settings determine what features are used for each circuit.
Channel 1
Status LED
LED Indications

Table 11-1 PGD(2)-U10 ADP LED Indications

LED
Indication
LED 1
Green LED when
CH1 in use.
LED 2
Green LED when
CH2 in use.
Setting up PGD(2)-U10 ADP Connections
If the PGD(2)-U10 ADP is to be wall mounted, all the cable connections
should be made first.
For the module to ID correctly after setting the jumpers, set the circuit type
to 0 for the module port in Program 10-03-01 prior to connecting the line
cord to the PGD(2)-U10 ADP.
Channel 2
Status LED

Figure 11-1 PGD(2)-U10 ADP

Flashing green LED indicates dipswitch setting
and programming for CH1 is conflicting.
Flashing green LED indicates dipswitch setting
and programming for CH2 is conflicting.
Installing SV8100/SV8300 Optional Equipment
UNIVERGE SV8100/SV8300
Note

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Univerge sv8300

Table of Contents