Install Cooling Fan; Chs2U-Us Chassis; Remove Cooling Fan; Figure 5-103 Chs2U-Us Chassis Access Panel - NEC Univerge SV8100 System Hardware Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100/SV8300
5.2
System Hardware Manual
5.1.2

Install Cooling Fan

1.
Align replacement fan with holes and secure with two screws
(refer to
5-74).
2.
Install cabling into retention clips (refer to
Access Panel Removed on page
3.
Insert access panel hinges into slots on rear of chassis.
4.
Plug fan power cable into three prong plug (refer to
5-101 Opening Chassis Access Panel (CHS1U-US Chassis)
on page
5.
Reinstall access cover and secure with retaining screw (refer to
Figure 5-100 CHS1U-US Chassis Access Panel on page

CHS2U-US Chassis

5.2.1

Remove Cooling Fan

To reduce the possibility of electrical shock or
damage to equipment, NEC recommends
powering Off the chassis and disconnecting the
AC cable from the power source before
removing the chassis cover.
1.
Ensure the chassis is powered down.
2.
Loosen retaining screw from chassis access panel.
Figure 5-102 Chassis Access Panel Removed on page
5-74).
To reduce the possibility of damage to
equipment, the installer must wear a
grounded wrist strap to protect the
equipment from static electricity.

Figure 5-103 CHS2U-US Chassis Access Panel

Issue 1.0
Figure 5-102 Chassis
5-74).
Figure
Retaining Screw
5-73).
5 - 75