NEC Univerge SV8100 System Hardware Manual page 154

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 1.0
Terminal
SMDR (LAN)
Hotel Server
Printer
6.2
3 - 20
Table 3-13 Cable Length of Optional Equipment (Continued)
Cable
Kind of Cable
LAN Cable (UTP
cable10BASE-T/
100BASE-TX)
LAN Cable (UTP
cable10BASE-T/
100BASE-TX)
RS-232C Cable
(RS PRT-15S CA-F)
Power Requirements
A dedicated 110 VAC
chassis is required. A separate dedicated outlet for each chassis should be
installed.
Double Pole/Neutral Fusing
(power supply fuses are located at both the L and N side).
6.2.1
Power Supply Specifications
AC Power Supply:
Dedicated 15 Amp circuit
Power Requirements: 120 VAC @ 15A Controlling Chassis Power
Consumption: Controlling Chassis=263 VA, Expa Chassis=263 VA,
total 526 VA
Input Voltage: 90 VAC to 264 VAC
(Rated Voltage: 100 VAC/120 VAC/220 VAC/230 VA /240 VAC)
Frequency: 45 Hz - Bt66 Hz (Rated frequency: 50/60 Hz)
Phase and Wire: Single Phase 2 Line Type + PE Type
Grounding Requirements: No.14 AWG copper wire
Feeding Voltage: Digital Multiline Terminal/OPX/DID: -48V
SLT: 25mA / -28V
With input voltage of 120 VAC and with full load conditions:
AC Input I: Controlling Chassis=2.19A, Expansion Chassis=2.19A,
total 4.38A
Cable Length between
SV8300 and Terminal
Pair
2-pair
328 ft (100m) or less
2-pair
328 ft (100m) or less
50 ft (15m)
120 VAC 60 Hz circuit located within seven feet of the
UNIVERGE SV8100/SV8300
Remarks
SV8300 System Specifications

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Univerge sv8300

Table of Contents