Table 11-4 Rj-61 Cable Connector - NEC Univerge SV8100 System Hardware Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100/SV8300
13.2
13.3
System Hardware Manual
When connecting the RJ-61 cables to the COIU Blade,
note the position of the Power Failure connector. Do not
confuse connector CN3 as the CN2 trunk connector.
Connector Pin-Outs on COIU Blade for Power Failure Circuits

Table 11-4 RJ-61 Cable Connector

RJ-61 Cable Connector - CN13, SLT Interface for Power Failure
Installing the Power Failure Telephones
1.
Connect an RJ-61 connector to the COIU Blade installed in the system.
2.
Install a modular jack for each single line telephone supporting PF
operation. The modular jack should be within six feet of the phone.
3.
For each extension, run one-pair 24 AWG station cable from the cross-
connect block to a modular jack.
4.
Terminate the extension leads to GRN/RED of the modular jack.
Terminate the unused leads to the jack. Refer to
Failure Connector (CN3) Shown on CD-4COTB Blade on page
Pin No.
1
2
3
4
5
6
7
8
Issue 1.0
Connection
Circuit 2 - Tip
Circuit 1 - Ring
Circuit 1 - Tip
Circuit 2 - Ring
Figure 11-72 Power
11-90.
11 - 89