NEC Univerge SV8100 System Hardware Manual page 605

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100/SV8300
E
S
5
XTERNAL
ECTION
5.1
5.2
System Hardware Manual
P
AGING
External Page
Two external page zone/door box circuits are provided by each PGD(2)-U10
ADP installed. Each Door Box/external page circuit provides a dry relay
contact. The CD-CP00-US also provides a connection for external paging and
a relay. The external page on the CD-CP00-US is speaker number 9 - the
relay is number 0. The external page speakers provided by the PGD(2)-U10
ADPs are 1-8 – the relays on the PGD(2)-U10 ADPs are numbered 1-8.
The PGD(2)-U10 ADP can be used for talkback with External Page, as can a
CO trunk port with the proper external page equipment (ex: Valcom) – set
Program 31-06-03 to "0" for talkback. However, the external page circuit on
the CD-CP00-US cannot be used for talkback.
A PGD(2)-U10 ADP circuit used for External Paging
cannot also be used for an analog Door Box.
Installing an External Page System
1.
Connecting to the CD-CP00-US:
Connect an RCA line from the CN8 or CN9 connector on the
CD-CP00-US to the appropriate location on the extension cross-connect
block.
2.
Connect the two-conductor station cable from the cross-connect block to
the external relay/external page.
3.
Install bridging clips as required.
OR
1.
Connecting to the PGD(2)-U10 ADP:
Make sure the jumper in the PGD(2)-U10 ADP for the channel is set
correctly. (Refer to Figure 11-4
page 11-4).
2.
If a line cord was not previously connected to the PGD(2)-U10 ADP,
complete Steps 3-6. Otherwise, skip to Step 7.
3.
Install a modular jack for each PGD(2)-U10 ADP. For each module, run
one-pair 24 AWG station cable from the cross-connect block to a
modular jack. Ground the unused pair.
PGD(2)-U10 ADP Jumper Settings
Issue 1.0
on
11 - 15