Issue 3.0
4.2
E
S
5
NVIRONMENTAL
ECTION
5.1
5 - 12
KWh @ AC Input I x 120V/1000: Base chassis=0.263 KWh,
Expansion chassis=0.263 KWh, total 1.052 KWh
BTU (KWh x 3413): Base chassis=898 BTU,
Expansion chassis=898 BTU, total 3592 BTU
Double Pole/Neutral Fusing (power supply fuses are
located at both the L and N side).
Dedicated 120 Vac
60 Hz circuit located within seven feet of the chassis
Dedicated 15A circuit
Single Phase
A dedicated outlet, separately fused and grounded for each chassis should
be installed
Double Pole/Neutral Fusing (power supply fuses are
located at both the L and N side).
Power Supply Consumption
Chassis
Basic Chassis – CD-CP00-US Chassis
Basic Chassis + Expansion Chassis
Basic Chassis + 2 Expansion Chassis
Basic Chassis + 3 Expansion Chassis
C
ONDITIONS
Temperature and Humidity
Chassis, Telephones, BCH, BHA, 16LK, Console, ADA, APR
Operating Temperature: +32°F ~ +104°F (0°C ~ 40°C)
Recommended Long Term Temperature: -4°F ~ +140°F (-20°C ~ 60°C)
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 90% RH
Table 5-9 Power Consumption
Maximum
RMS
Current
2.19A
4.38A
6.57A
8.76A
UNIVERGE SV8100
Watts Used
Watts Used
(Idle)
(Maximum)
96
130
192
260
288
390
384
520
Hardware Specifications