PARAMETER OVERVIEW

7 Operator Parameters

7.1 Parameter overview
The operator parameters are managed by the F5 PROFINET operator. No transmission
to the drive converter control is necessary on access to these parameters. Only the
parameters which are interesting for the user are listed here. All not listed parameters
should not be changed by the user. Each parameter is described via the name or a short
identifier (ID). Like the drive converter parameters, the parameters are also arranged in
parameter groups. The ID is made up of the code for the parameter group and the serial
number of the parameter. Currently the following parameter groups are available in the
F5 PROFINET operator:
The following is valid for all operator parameters and all drive converter parameters:
PNU = COMBIVIS parameter address
Sub-In-
PNU
ID
dex (*1)
0180h
0
OS00 OS00: Operator type
0181h
0
OS01 Password
0182h
0
OS02 Software date
0185h
0
OS05 Diag Baud rate
0189h
0
OS09 HSP5_MinTxGap
018Ah 0
OS10 MAC Address
018Bh 0
OS11 NetX_FwVersion
018Ch 0
OS12 Serial Number
018Dh 0
OS13 QS number
018Eh 0
OS14 NodeSwitchVal
018Fh
0
OS15 Pnet_IPAddress
0190h
0
OS16 Din66019SlvAddr
0191h
0
OS17 MAC Address(Port0)
(*1)
Please note that the use of the sub-index is depending on the actual setting of bit6 in parameter
Fb01 FBS Config, see chapter "3.1.1.2 Addressing with subindex". „3.1.1.2 Satzadressierung
mittels Subindex"
34
Operator system (OS)
Fieldbus (Fb)
Debugging (Db)
Name
(Chassis)
Internal
Meaning
data type
Uint32
Operator type + software version
Int16
Read: Actual password level
Write: Password value
Uint16
Software date in terms of: Year,MMDD
Transmission speed of the diagnostic
interface
Uint16
Minimum HSP5-Tx-time gap in µs
Uint32
Least significant 32-bit MAC address of
the operator
Uint32
Firmware version of the PROF-
INET-Asics
Uint32
Serial number of the operator
Uint16
KEB internal
Uint8
Value of the two hex coding switches at
the front of the operator
Uint32
From PROFINET master preset IP-ad-
dress of the operator
Uint8
Slave address of the operator for the
addressing via UDP/IP
Uint32
Less significant 32-Bit of the MAC ad-
dress for Port0 (X6C) of the operator

Hide quick links: