Craft Port; X.25/Admin Port; Table 12. Craft Port Connector Pin Assignments - ADTRAN OPTI-6100 Installation Manual

Installation and turn-up practice
Hide thumbs Also See for OPTI-6100:
Table of Contents

Advertisement

Craft Port

The SCM provides an RS-232 serial asynchronous craft access port. Physical access is attained
by way of a female DB-9 connector on the SCM front panel. The craft port can operate from
9600 to 115200 baud (the default rate is 9600 baud.) The format is 8-bit asynchronous data
with no parity and one stop bit (8, N, 1). Minimal 3-wire functionality (pins 2, 3, and 5) is also
accommodated. The craft port operates as a DCE (Data Communication Equipment).
Table 12
lists the detailed pin assignments for the SCM craft port.

Table 12. Craft Port Connector Pin Assignments

NOTE
The Craft and Admin ports both default to 9600 baud, but have
available rates of 19200, 38400, 57600, and 115200. If set to an
unsupported value, restore the baud rate by the following method:
1. Remove the SCM from the OPTI-6100 chassis.
2. Reinstall the SCM, holding the ACO pushbutton for 10 seconds.
3. Log in to the system.
4. Select

X.25/ADMIN Port

The SCM includes an RS-232 compatible serial interface, accessed via a female DB-25
connector (
/
) on the rear panel of the OPTI-6100 chassis, labeled
J31
J18
operates as a DTE (Data Terminal Equipment) and is configured for the following settings:
1-way in or 2-way operation
Up to four SVCs
Up to 64 kbps (DCE provides clock)
Packet size:
Packet window:
n2 retry limit:
T1 ACK timer:
T3 time out:
k window size:
61184500L1-5L
Pin Number
Function
2
Transmit Data from DCE
3
Receive Data into DCE
4
Data Terminal Ready (DTR)
5
Signal Ground
Run Primary SCM Application (Flash)
128 bytes
2
3
20 seconds
3 seconds
2
to exit Boot ROM.
X.25/ADMIN
System Management
. This port
57

Hide quick links:

Advertisement

Table of Contents
loading