Auxiliary # Input Menu
Main\System Alarms\User-Definable Alarms\Environmental
Auxiliary # Input
Use the Auxiliary # Input menus
TID: HSV00001
Unacknowledged Alarms: None
Selection :
Table 111
lists the options in the Auxiliary # Input menus.
Option
Description
1
Auxiliary # Input
Description
2
Auxiliary # Input
Level
3
Auxiliary # Input
AID Index
4
Auxiliary # Input
Condition Code
5
Power Supply
Decoding
61184500L1-5L
Alarms\Auxiliary # Input\
(Figure
OPTI-6100 System
Auxiliary #1 Input
1.
Auxiliary #1 Input Description
2.
Auxiliary #1 Input Level
3.
Auxiliary #1 Input AID Index
4.
Auxiliary #1 Input Condition Code : AUX-1
5.
Power Supply Decoding
'?' - System Help Screen
Figure 119. Auxiliary #1 Input Menu
Table 111. Auxiliary # Input Menu Options
Function
This option sets the auxiliary alarm input description.
The default is
This option sets the alarm level reported for an auxiliary alarm input.
The available options are as follows:
♦
Info
Alert
♦
Minor
♦
♦
Major (default)
Critical
♦
This option sets the AID Index for the auxiliary alarm input.
The valid range is 1–64. Defaults are 1, 2, and 3, respectively.
This option sets the TL1 Condition Codes for the auxiliary alarm input.
The default is
This option enables/disables power supply decoding.
Select Enable or Disable (default).
119) to provision auxiliary alarm inputs #1–3.
: Aux #1 Input
: MAJOR
: 1
: DISABLE
. <n>= 1, 2, or 3, respectively.
Aux #<n> Input
, where <n>= 1, 2, and 3, respectively.
AUX-<n>
OPTI-6100 Main Menu
MM/DD/YY hh:mm
MX Chassis:
1
205