Table 146
lists the minimum factory defaults and values that are loaded after installation and
self-test for the DS3M3E module.
Provisioning Options
Equipment Provisioned State
AINS Time
AINS Timer
Loopback Timeout
Loopback Timer
Facility #1–3 Provisioned State
Facility #1–3 DS3 Framing
Facility #1–3 Line Build Out
Facility #1–3 DS3 FEAC Loopback Code Detection
Facility #1–3 Line Identification
Facility #1–3 Alarm Reporting
Board Operating Mode
PRI Clock Output to OMM*
SEC Clock Output to OMM*
Auto Framing
1. Use Short for distances of less than 225 feet of 728A/734A coax, or 125 feet of 735A coax.
2. EC1 Operating Mode only
61184500L1-5L
Table 146. DS3M3E Provisioning Options
Tributary Module Installation and Turn-Up
Settings
♦
IS
OOS-MA
♦
OOS-MA UAS (default)
♦
1 Minute to 96 Hours; 4:00 is the default
Enabled (default)
♦
♦
Disabled
1 Minute to 96 Hours; 2:00 is the default
♦
Enabled
Disabled (default)
♦
IS
♦
♦
OOS-MA
♦
OOS-MA UAS (default)
Auto (default)
♦
M13
♦
♦
CBIT
♦
Unframed
♦
Short (default)
Long
♦
♦
Short, Low
♦
Enabled
♦
Disabled (default)
(enter text)
Enabled (default)
♦
Disabled
♦
DS3 (default)
♦
♦
EC1
♦
Disabled (default)
Facility 1
♦
Disabled (default)
♦
♦
Facility 1
♦
Enabled (default)
♦
Disabled
283