Table 146. Ds3M3E Provisioning Options - ADTRAN OPTI-6100 Installation Manual

Installation and turn-up practice
Hide thumbs Also See for OPTI-6100:
Table of Contents

Advertisement

Table 146
lists the minimum factory defaults and values that are loaded after installation and
self-test for the DS3M3E module.
Provisioning Options
Equipment Provisioned State
AINS Time
AINS Timer
Loopback Timeout
Loopback Timer
Facility #1–3 Provisioned State
Facility #1–3 DS3 Framing
Facility #1–3 Line Build Out
Facility #1–3 DS3 FEAC Loopback Code Detection
Facility #1–3 Line Identification
Facility #1–3 Alarm Reporting
Board Operating Mode
PRI Clock Output to OMM*
SEC Clock Output to OMM*
Auto Framing
1. Use Short for distances of less than 225 feet of 728A/734A coax, or 125 feet of 735A coax.
2. EC1 Operating Mode only
61184500L1-5L

Table 146. DS3M3E Provisioning Options

Tributary Module Installation and Turn-Up
Settings
IS
OOS-MA
OOS-MA UAS (default)
1 Minute to 96 Hours; 4:00 is the default
Enabled (default)
Disabled
1 Minute to 96 Hours; 2:00 is the default
Enabled
Disabled (default)
IS
OOS-MA
OOS-MA UAS (default)
Auto (default)
M13
CBIT
Unframed
Short (default)
Long
Short, Low
Enabled
Disabled (default)
(enter text)
Enabled (default)
Disabled
DS3 (default)
EC1
Disabled (default)
Facility 1
Disabled (default)
Facility 1
Enabled (default)
Disabled
283