Table 137. Ds1M/Ds1M2 Provisioning Options - ADTRAN OPTI-6100 Installation Manual

Installation and turn-up practice
Hide thumbs Also See for OPTI-6100:
Table of Contents

Advertisement

OPTI-6100 Installation and Turn-Up Practice
Table 137
lists the minimum factory defaults and values that are loaded after installation and
self-test for the DS1M/DS1M2 modules.
Provisioning Options
Equipment Provisioned State
AINS Time
AINS Timer
DS3 Framing
DS3 FEAC Loopback Code Detection
Facility Provisioned State, DS1 1–28
Facility Provisioned State, DS3
(Backplane)
DS1 Line Length, Facility 1–28
DS1 Line Coding, Facility 1–28
DS1 In-Band Loopback Code Detection,
Facility 1–28
DS1 Line Identification, Line 1–28
PRI Clock Output to OMM
SEC Clock Output to OMM
258

Table 137. DS1M/DS1M2 Provisioning Options

Settings
IS
OOS-MA
1 Minute to 96 Hours; 4:00 is the default
Enabled
Disabled (default)
C-BIT (default)
M13
Enabled
Disabled (default)
IS
OOS-MA
IS
OOS-MA
0–133 Feet (default)
134–266 Feet
267–399 Feet
AMI
B8ZS (default)
Disabled (default)
NIU
CSU
(enter text)
Disabled (default)
Facility 1
Facility 2
Disabled (default)
Facility 1
Facility 2
OOS-MA UAS (default)
OOS-MA UAS (default)
OOS-MA UAS (default)
400–533 Feet
534–655 Feet
61184500L1-5L