Table 54. Snmp Menu Options - ADTRAN OPTI-6100 Installation Manual

Installation and turn-up practice
Hide thumbs Also See for OPTI-6100:
Table of Contents

Advertisement

Table 54
lists the options in the SNMP menu.
Option
Description
1
Trap Host 1 IP
2
Trap Host 2 IP
3
Trap Host 3 IP
4
Trap Host 4 IP
5
SCM Traps
6
System Name
7
TID/SysName Sync
8
System Location
9
System Contact
10
Read Community
11
Write Community
12
NonVol CardStat
61184500L1-5L

Table 54. SNMP Menu Options

Function
This option sets the IP address for SNMP trap host 1.
This option sets the IP address for SNMP trap host 2.
This option sets the IP address for SNMP trap host 3.
This option sets the IP address for SNMP trap host 4.
This option enables/disables SNMP traps on the SCM.
Select Enabled (default) or Disabled.
This option is a label, up to 55 characters, used to identify the system.
For example:
XYZ Co. OPTI-6100
This option enables/disables TID/SysName Sync, which automatically
copies the TL1 Target Identifier to the SNMP System Name (above).
Refer to
"TL1 Menu"
on page 122.
Select Enabled or Disabled (default).
This option is a label, up to 55 characters, to identify a system location.
For example:
Telephone utility closet, 3rd floor
This option is a label, up to 55 characters, to identify the person(s)
responsible for maintaining the system.
For example:
Joe Smith – (212) 555-1234
This option is a label, up to 32 characters, to specify the SNMP
community for read access.
The default value is
public
This option is a label, up to 32 characters, to specify the SNMP
community for write access.
The default value is
private
This option specifies whether the SCM stores status information for
each module in non-volatile system memory across a controller reset.
Select Enabled or Disabled (default).
.
.