Single Fan Input Menu
Main\System Alarms\User-Definable Alarms\Environmental Alarms\Auxiliary Fan Alarms\Auxiliary Fan Alarm
Single Fan/Pwr
Use the Single Fan Input menu
TID: HSV00001
Unacknowledged Alarms: None
Selection :
Table 114
lists the options in the Single Fan Input menu.
Option
Description
1
Single Fan Input
Description
2
Single Fan Input
Level
3
Single Fan Input
AID Index
4
Single Fan Input
Condition Code
61184500L1-5L
(Figure
123) to provision single-fan/power alarms.
OPTI-6100 System
Single Fan Input
1.
Single Fan Input Description
2.
Single Fan Input Level
3.
Single Fan Input AID Index
4.
Single Fan Input Condition Code
'?' - System Help Screen
Figure 123. Single Fan Input Menu
Table 114. Single Fan Input Menu Options
Function
This option specifies the single fan/power failure alarm description.
The default is
This option sets the alarm level reported for a single fan/power failure.
The available options are as follows:
Info
♦
Alert
♦
♦
Minor (default)
Major
♦
Critical
♦
This option sets the AID Index for a single fan/power failure.
The valid range is 1–64. The default is 6.
This option specifies the TL1 Condition Code for a single fan/power
failure.
The default is
: Single Fan/Pwr
: MINOR
: 6
: CLFAN
.
Single Fan/Pwr
.
CLFAN
OPTI-6100 Main Menu
Inputs\Single Fan/Pwr\
MM/DD/YY hh:mm
MX Chassis:
1
209