OPTI-6100 Installation and Turn-Up Practice
MX Chassis Features
The basic features of the OPTI-6100 MX chassis are as follows:
Dimensions: 3.5 inches (2U) High × 12.0 inches Deep × 17.5 inches Wide
♦
19-inch or 23-inch rack mountable; flush-mount from rear or mid-mount from front
♦
Redundant –48 VDC or ±24 VDC power inputs (A and B feeds)
♦
Rear-panel connections:
♦
Champ connectors (3 IN/OUT pairs, 84 connections) for DS1 circuits
◊
BNC connectors (12 IN/OUT pairs, 24 connections) for DS3 or STS-1 circuits
◊
RJ-45 Ethernet management interface
◊
DB-25 X.25/Admin port interface
◊
Wire wrap pins for the RS-485 interface, alarms, and BITS timing
◊
Front-access connections:
♦
Optical fibers (OMM and optical tributary modules)
◊
Ethernet tributary modules
◊
DB-9 craft access to SCM
◊
RJ-45 Ethernet management with SCM2
◊
Convection or forced cooling with fan packs; may be required, depending on application
♦
Operates in Terminal mode or UPSR mode
♦
Fifteen module slots:
♦
1 slot for the System Controller Module (SCM or SCM2)
◊
2 high-speed (HS) slots for Optical Multiplexer (OMM) modules, supporting OC-3,
◊
OC-12, or OC-48 interfaces
12 mid-speed (MS) slots for tributary modules, arranged in pairs for the optional redun-
◊
dancy of certain modules, accommodating the following tributary interfaces:
• DS1
• DS3
• EC1 (STS-1)
4
• 10/100/1000 Ethernet (Copper and Optical)
• OC-3
• OC-12
61184500L1-5L