Table 92. Auto Upgrade Status Fields - ADTRAN OPTI-6100 Installation Manual

Installation and turn-up practice
Hide thumbs Also See for OPTI-6100:
Table of Contents

Advertisement

OPTI-6100 Installation and Turn-Up Practice
Table 92
lists the status fields in the Auto Upgrade Status menu.
Field
Description
Upgrades
This field displays the number of completed module upgrades.
Errors
This field displays the number of errors that have occurred since Auto Upgrade began.
Discovered
This field displays the number of modules Auto Upgrade detects in the chassis.
Needed
This field displays the number of upgrades needed, according to the current .auc file.
Active
This field displays the number of modules currently being upgraded.
Shelf
This field displays the current status of the chassis as it relates to Auto Upgrade.
Slot
This field displays the current status of each slot, as affected by the current Auto
Upgrade process. The following block represents a typical Status report while Auto
Upgrade is in progress:
Upgrades: 1/x Errors: 0/x Upgrades needed: 2
Shelf (00:05:26): Busy, upgrading slot 8 (1184510L1)
Slot (8, 00:01:33): Busy, send file to module, 43.2% (1184510L1)
This block indicates the following:
One successful module upgrade has already been completed.
No upgrade errors have occurred since the last Auto Upgrade operation.
Two modules (including the current one in slot 8) require firmware upgrade.
The chassis is busy upgrading an 1184510L1 (ETHM) module in slot 8 and has been
performing Auto Upgrades for 5 minutes and 26 seconds.
The current module in slot 8 has been in the process of an upgrade for 1 minute and
33 seconds. The SCM has already retrieved the firmware file from the TFTP server
(or from the local TFTP Cache). The SCM is in progress sending the firmware file to
the module, and is 43.2% complete.
The following block and associated hot keys display the Auto Upgrade status or progress
of any slot in the chassis, regardless of which module is currently being upgraded. This
helps determine which modules require a firmware upgrade and which are up-to-date.
Slot (11, 00:00:00): Idle, 1184510L1 needs upgrade (A05 -> A06)
This example indicates the state of the module in slot 11:
The module status is Idle
The module type is 1184510L1 (ETHM module)
The module needs a firmware upgrade
178

Table 92. Auto Upgrade Status Fields